MARS 110R, 110, 210, GC2R, and GC2 Front and Back Panels

AC Power Source Requirements

Each power supply has a socket to accommodate an AC power cord. Each power supply operates within
the parameters listed in
Table 1-14
Parameter
Minimum
Rated
Maximum
Start-up VAC
Power Off VAC
Maximum Input AC Current
Maximum Rated Input AC Current
Frequency
1. Maximum input current at low input voltage range is measured at maximum load—minimums are 90VAC for
2. Maximum rated input current is measured at 100VAC and 200VAC.

Power Supply LED Descriptions

Each power supply module has a two-color Amber/Green LED to indicate power supply status.
Install and Setup Guide for Cisco Security MARS
1-28
Table
Power Supply Maximums and Minimums—MARS 110R, 110, 210, GC2R, and GC2
1
a 110 Line, and 180VAC for a 220 Line.
Solid amber—Indicates no AC power for this power supply unit only, or there is a power supply
critical event causing a shutdown. For instance, a general failure, a blown fuse, an over-current
protection event, an over-voltage protection event, or a fan failure.
1Hz blinking amber— Power supply warning event is occurring and the power supply is operating.
Warning events are high temperature, high power, high current, or slow fan.
Solid green—Power supplies are operating normally
1Hz blinking green—AC power is present but only 5V standby is on (Power Button is off)
1-14.
110 Line Voltage
rms
90 V
rms
100–127 V
rms
140 V
85 VAC +/– 4 VAC
75 VAC
rms
12.0 A
2
rms
11.0 A
Minimum: 47 Hz; Rated: 50/60 Hz; Maximum: 63 Hz
Chapter 1
Appliance Overview and Specifications
220 Line Voltage
rms
180 V
rms
200–240 V
rms
264 V
rms
6.0 A
rms
5.5 A
OL-14672-01