Parameter setting

It is necessary to set the output mode to "waveform output mode".
Navigation window  [Parameter]  [Module Information]  [FX5-4DA]  [Module Parameter]  "Basic setting" 
"Operation mode setting function"  "Output mode setting"
For the parameter setting procedure, refer to MELSEC iQ-F FX5 User's Manual (Analog Control - Intelligent function
module).

Example of use

An example of the use of this FB is shown.
System Configuration
For an example of system configuration, refer to Page 10 Analog output module FB.
Outline of program
Set the waveform patterns using eight points from CH1 of FX5-4DA as shown below to repeat the output infinitely in a 500-ms
cycle. CH2 to CH4 are not used.
Waveform pattern for
cyclical analog output
[Digital value]
6
5
4
3
2
1
0
1
2
3
4
5
6
7
[Digital value]
6
5
4
3
2
1
0
8
Number of
data items
1 cycle
Waveform pattern with cyclical analog output
1 cycle
3 ANALOG OUTPUT MODULE FB
3.3 M+FX5-4DA_WaveOutputSetting (Waveform output setting)
Repeated
below
1 cycle
31