Soll totem durahoist post
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
(*) The instructions for assembly are given for fixing HILTI HVUHAS-R M12x110 chemical
anchors.
B4. Bolting through the steel supporting structure:
- The bolt-on collar of the SÖLL TOTEM DURAHOIST POST MILLER must be
fastened using eight M12 A4-70 bolts, M12 A4 nylstop locknuts and washers
suitable for a rigid steel foundation, as indicated in Fig. B3. The supporting
structure must be of a minimum thickness of 6mm.
- The holes in the supporting structure must be 13mm to 14mm.
- The installer shall be responsible for preventing corrosion and, if necessary, for
ensuring watertightness of the roof. The base is in 316 grade stainless steel.
B5 – Fixing to a concrete support
- The SÖLL TOTEM DURAHOIST POST MILLER collar for concrete must be used
for all concrete supports. This collar is fixed to the support using four HILTI
HVU-HAS-R M12x110 chemical anchors (stainless steel) or equivalent (*).
For installations with the following features:
- C20/25 non-cracked concrete
- Plain concrete or distance between frameworks>= 150mm (all Ø) or >= 100mm
(<= 10mm),
observe the instructions below
For assembly using a different fixing system from that recommended, ensure
performances are the same and observe the manufacturer's instructions.
(1) Th: minimal thickness of the concrete support according to the temperature
ranges of the concrete during the life span of the work (see table below)
(2) Assembly must take place with strict observation of the instructions stated in
the product leaflet of the HILTI HVU-HAS-R M12x110 chemical anchors.
Temperature range
Temperature of support material
(°C)
Long term temperature (°C)
Short term temperature (°C)
Th (mm)
Fig. B7
4x HILTI HVU-HAS-R M12x110
I
-40 / +40
-40 / +80
+24
+40
140
(2)
2
II
-40 / +120
+50
+80
170
III
+72
+120
210