Message Codes - Makita SK105GD Manual

Hide thumbs Also See for SK105GD:
Table of Contents

Advertisement

Available languages

Available languages

Message Codes

Me s s a g e Co d e s
Laser
ON
ON
ON
OFF
OFF
Blinks
Blinks
Blinks every 5 seconds
Blinks every 5 seconds
Blinks every 5 seconds
Makita SK105D/SK105GD
LED
Lights green
Blinks green
Lights red
Lights red 5 seconds then OFF
Blinks red
Lights red
Blinks red
Lights red
Lights green
Blinks green
Cause
Normal
Normal, laser set at reduced
brightness
Instrument is at low power
Battery empty
Temperature alert
Instrument is out of self-levelling
and instrument is at low power
Instrument is out of self-levelling
Levelling lock is activated and
instrument is at low power
Normal, levelling lock is activated
Levelling lock is activated and
laser set at reduced brightness
Correction
-
OK - or press ON / Set key for 2
seconds to get strong laser beam
Change power supply
Change power supply
Cool down - or
heat up instrument
Change power supply
Position the instrument almost
horizontal
Change power supply
-
-
13