Advertisement

Table of Contents

- - - - - - - - - - - - - - - - - - - - - - - 2
Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Overview - Laser - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Overview - Receiver - - - - - - - - - - - - - - - - - - - - - - - - 4
Overview - Remote Control - - - - - - - - - - - - - - - - - - - 5
Accessories - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
Typical uses - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
Switching ON / Automatic mode - - - - - - - - - - - - - - - - 8
Switching OFF - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8
Manual mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8
H.I. Alert mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
- - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Rotating - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Scanning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
Ceiling work - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
Layout or floor work - - - - - - - - - - - - - - - - - - - - - - - - 13
Level fixing points - - - - - - - - - - - - - - - - - - - - - - - - - 14
Water pipe assembly - - - - - - - - - - - - - - - - - - - - - - - 14
Floor leveling - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
Formwork leveling - - - - - - - - - - - - - - - - - - - - - - - - - 15
Level accuracy - - - - - - - - - - - - - - - - - - - - - - - - - - - 16
Vertical accuracy- - - - - - - - - - - - - - - - - - - - - - - - - - 16
- - - - - - - - - - - - - - - - - - - - - - - - - 17
- - - - - - 11
- - - - - 12
- - - - - - - - - - - - - - - - 13
- - - - - - - - - - - - - - - - - 16
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -18
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -18
Areas of responsibility - - - - - - - - - - - - - - - - - - - - - -19
Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - -19
Limits of use - - - - - - - - - - - - - - - - - - - - - - - - - - - - -19
Prohibited use - - - - - - - - - - - - - - - - - - - - - - - - - - - -19
Noise emissions (laser receiver) - - - - - - - - - - - - - - -20
Hazards in use - - - - - - - - - - - - - - - - - - - - - - - - - - -20
Disposal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -20
Electromagnetic Compatibility (EMC) - - - - - - - - - - - -21
FCC statement (applicable in U.S.) - - - - - - - - - - - - -21
Laser classification- - - - - - - - - - - - - - - - - - - - - - - - -22
Labelling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -22
Makita SKR200
- - - - - - - - - - - - - - - - - - -18
- - - - - - - - - - - - - - - - - - - - -19
EN
1

Advertisement

Table of Contents
loading

Summary of Contents for Makita SKR200

  • Page 1: Table Of Contents

    Vertical accuracy- - - - - - - - - - - - - - - - - - - - - - - - - - 16 Technical Data - - - - - - - - - - - - - - - - - - - - - - - - - 17 Makita SKR200...
  • Page 2: Instrument Set-Up

    Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner. Makita SKR200...
  • Page 3: Overview - Laser

    On / Off status/ tripod screw Battery status LED Manual LED H.I. Alert mode Battery replacement: Manual mode H.I. Alert Battery Positioning Positioning button - left button - right Battery empty Scan Rotation speed Integrated feet for laydown position Makita SKR200...
  • Page 4: Overview - Receiver

    Magnets (offset 50 mm / 2") ±1 mm (default) Beep On / Off Sensivity: coarse ±3 mm Sensitivity key Backside: Beep medium Magnetic mounting plate Beep high Display Beep off Battery replacement: Battery status: full Staff Battery status: Makita SKR200...
  • Page 5: Overview - Remote Control

    Instrument Set-up Overview - Remote Control Infrared outlet Positioning button - Up LED indicator Positioning button - Right Positioning button - Left Positioning button - Down Rotation / Scan Battery replacement: Key ring Makita SKR200...
  • Page 6: Accessories

    Holding clamp Scale cm/inch Fixing screw Mounting screw Adjustment screw Target plate: Goggles: Magnets WARNING! The goggles do not protect your eyes against the laser beam. It is only used to increase the visibility of the laser beam. Makita SKR200...
  • Page 7: Operations

    Operations Typical uses Receiver mounted on staff Laser mounted on tripod Receiver on the floor Laser in laydown position Laydown on the floor: Keypad has to be on the top side Mounted on wallmount, leveling with target plate Makita SKR200...
  • Page 8: Switching On / Automatic Mode

    In manual mode the laser beam will rotate even if the laser is not leveled. Manual mode can be used on inclined planes such as 2 sec stairs, ceilings or anytime a manual grade setting is Exit Manual required. mode Makita SKR200...
  • Page 9: H.i. Alert Mode

    The Elevation Alert or Height of Instrument function is designed to prevent incorrect work caused by sudden movement or settling of the tripod that would cause the laser to level at a lower height. Makita SKR200...
  • Page 10: Applications

    Applications Rotating 0 rpm 300 rpm 450 rpm 600 rpm Start rotating Change the rotation speed. Scanning Start scanning Change the scan angle. Makita SKR200...
  • Page 11: Button Functions - Upright Mode

    Button Functions - Upright Mode Rotation Mode Automatic Mode Manual Mode Scan Mode Automatic Mode Manual Mode Makita SKR200...
  • Page 12: Button Functions - Laydown Mode

    Button Functions - Laydown Mode Rotation Mode Automatic Mode Manual Mode Scan Mode Automatic Mode Manual Mode Makita SKR200...
  • Page 13: Alignment Applications

    Use the remote to 90° fine align the plumb laser beam parallel to the wall. Mark laser lines on the ceiling, wall 90° 90° and floor accordingly. Continue in the same way with the next drywall tracks. 90° Makita SKR200...
  • Page 14: Level Fixing Points

    Water pipe assembly Mount laser with Adjust the tube clamps to the the wallmount to laser beam. the wall. Switch to manual mode. Incline the laser beam to the reference. Mount and fix the water pipe. Makita SKR200...
  • Page 15: Floor Leveling

    Formwork leveling Switch on the laser. Use automatic mode or H.I. alert mode and allow the laser to self-level. Mount receiver with clamp on the staff. Pick up reference height. Adjust height needed for formwork. Level and adjust formwork. Makita SKR200...
  • Page 16: Checking The Accuracy

    Use automatic mode and allow the laser tolerance, please to self-level. Align the vertical beam to the contact a local plumb line. Use scan operation to have best dealer. visibility. If the vertical beam is not plumb, adjustment is necessary. Makita SKR200...
  • Page 17: Technical Data

    -4 to 158 °F ** Battery life is dependent upon environmental - Operation -10 to 50 °C 14 to 122 °F conditions *** Leakage proof alkaline batteries strongly Protection class IP54 (dust- and splash water protected) recommended Tripod Thread 5/8"-11 Makita SKR200...
  • Page 18: Transport

    Shipping, transport of batteries When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are observed. Before transportation or shipping, contact your local passenger or freight transport company. Makita SKR200...
  • Page 19: Safety Instructions

    • Opening the product using tools, for of the original equipment: means of a laser detector. example screwdriver, unless this is Makita Corporation Anjo, • This product is intended for indoor use specifically permitted for certain Aichi 446-8502 Japan and applications.
  • Page 20: Noise Emissions (Laser Receiver)

    If it is essential to work in this that the accessories are correctly adapted, environment, first contact the safety fitted, secured, and locked in position. authorities responsible for the electrical Avoid subjecting the product to installations and follow their instructions. mechanical stress. Makita SKR200...
  • Page 21: Electromagnetic Compatibility (Emc)

    • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Makita SKR200...
  • Page 22: Laser Classification

    WARNING Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous. CAUTION Looking into the laser beam may be hazardous to the eyes. Subject to change (drawings, descriptions and technical data) without prior notice. Makita SKR200...

Table of Contents