8.4. Environment
Environment specification Power Cabinet
Ingression protection
Temperature range – Operation
Temperature range – Storage
Humidity
Airflow
Pressure drop
Altitude
Storage conditions
Environment specification for the Dual Depot Charge Box
Ingression protection
Temperature range – Operation
Temperature range – Storage
Humidity
Altitude
Storage conditions
Warranty
Warranty will be considered void if the HVC-R 100/150 E-Bus Charger is
damaged due to being stored inappropriately by the Customer.
8.5. Certifications
Certifications for complete system
CE
Class of protection
Document: v0.4 / Document No.: TBA | Date: 11-08-2021
HVC-R 100/150 E-Bus Charger Installation Guide
IP54
-35 ºC to +45 ⁰C
-10 ºC to +70 ⁰C
5 % to 95 %, RH – non-condensing
3
1450 m
/h
300 Pa
2000 m (max.)
Indoors, dry
IP65 (excluding charge cable)
-35 ºC to +55 ⁰C
-10 ºC to +70 ⁰C
5 % to 95 %, RH – non-condensing
2000 m (max.)
Indoors, dry
CAUTION
Declaration of Conformity HVC150: 20160609
1 with PE connection
Page 119 of 131