Table 8-1
Contents of revision of SPARC M10 Systems Installation Guide (continued)
Section number or name
4.3.2
5.2
5.3
5.4
6.1
Changing crossbar cable (case in which the
expansion rack 2 is added later)
2.
Move the crossbar cable (optical) for XBBOX#80/#81.
a. Remove the crossbar cables between L4 and L7 and between R4 and R7
b. Reattach the labels of the removed cables.
c. Connect the crossbar cables from L0 to L3 and from R0 to R3 of the
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2043 ・ October 2013
80
Contents of revision
Step 2 described in "4.3.2 Connecting crossbar cable" will be changed as follows:
2. Connect the crossbar cable to the crossbar box.
Cross bar cables are laid out in a bundle for each cabinet. Connect cables without
changing the way they are laid out.
Connect the cables so that the port indicators on each cabinet match the labels on
the cables. There are two ports with the same port number. Each port on the
cabinet is color-coded. Connect a port to the corresponding port with the same
color.
Hold the connector part of the crossbar cable (optical) and insert it straight into
the opening. Do not hold the cable part when inserting the cable.
The note in Step 1 in "5.2 Connecting Cable to SPARC M10-4/SPARC M10-4S" will
be changed as follows.
Note-Normally, BB#00 is the master XSCF and BB#01 is the standby XSCF. When
the master is switched, BB#01 is the master XSCF and BB#00 is the standby
XSCF.
Two notes in Step 2 in "5.3 Connecting Cable to PCI Expansion Unit" will be
changed. For details, see
The note in Step 1 in "5.4 Connecting Cable to Crossbar Box" will be changed as
follows.
Note-Normally, XBBOX#80 is the master XSCF and XBBOX#81 is the standby
XSCF. When the master is switched, XBBOX#81 is the master XSCF and
XBBOX#80 is the standby XSCF.
The note in Step 2 in "6.1 Connecting System Management Terminal to the Cabinet"
will be changed as follows.
Note-When each cabinet is directly connected, normally BB#00 is the master XSCF
and BB#01 is the standby XSCF. When connection is made through a crossbar
box, normally XBBOX#80 is the master XSCF and XBBOX#81 is the standby
XSCF. When the master is switched, BB#01 or XBBOX#81 is the master XSCF
and BB#00 or XBBOX#80 is the standby XSCF.
of the crossbar unit #1.
Hold the tab (A in Figure 8-1) of the crossbar cable (optical), and pull it
straight in the arrow direction to remove it. At this time, do not pull out the
crossbar cable by holding the cable part. If you pull the cable part, the
connector is not unlocked completely, which may cause a damage.
The labels for reattachment are included with the expansion rack 2.
"Connecting Cable to PCI Expansion
Unit."