Table 3-3
Problems resolved in versions prior to XCP 2043 (continued)
SPARC
RTI No.
M10-1
RTIF2-130109-
006
RTIF2-130109-
x
007
RTIF2-130130-
001
SPARC
SPARC
M10-4
M10-4S
Description
x
If you change the setting
information of the power
supply interlocking function
while the standby XSCF is in
failure or starting, the changed
setting information may not be
reflected in the standby XSCF
even after the start of the
standby XSCF is completed.
If XSCF switching occurs in this
state, the master XSCF after the
switching may not be able to
achieve power supply
interlocking based on the
changed setting information.
x
x
If all physical partitions
(PPARs) are stopped and you
try to power on a PPAR, the
PPAR may not be powered on
with no error log registered.
x
x
If you turn on the AC in a
system configuration with no
CMUU mounted, an error log of
Hardware access error is
generated for CMUU. The same
phenomenon occurs when you
add or replace SPARC M10-4S.
Workaround
Disable the power supply
interlocking function, and then
configure it again using the
following procedure:
1. Execute the setremotepwrmgmt
-c disable command to disable
the power supply interlocking
function.
2. Save the management file,
and then use the
clearremotepwrmgmt(8)
command to initialize the
setting information.
If the standby XSCF is
starting, execute the
clearremotepwrmgmt(8)
command after the start is
completed.
If the standby XSCF is in
failure, use the replacefru(8)
command to replace the
target FRU, and then execute
the clearremotepwrmgmt(8)
command.
3. After the start of the standby
XSCF is completed, execute
the setremotepwrmgmt -c
config command to restore the
setting information based on
the saved management file.
4. Execute the setremotepwrmgmt
-c enable command to enable
the power supply interlocking
function.
There is no effective workaround.
Tun off the input power supply
and turn it back on to all
SPARC M10 system cabinets
and then try to power on the
PPAR again.
The error log is registered
because no CMUU is mounted.
So, ignore it.