LED indicator / Beeper
► Fig.6: 1. LED indicator
LED indicator / Beeper on the tool shows the following functions.
Function
Check of the LED indi-
cator, light and beeper
operation
Detection of switch
trigger operation when
installing battery
Auto-stop with fastening
completion
Alarm against insuffi-
cient fastening
Intermission between
the phases
Double-hitting detection
Alarm for low battery
capacity
Auto-stop with low
remaining battery
capacity
Anti-reset of controller
Overheat protection
Failure to detect heat
of motor
Motor failure detection
Maintenance alarm
Alarm for unavailable
data communication
(with the tool in connec-
tion with PC)
Indication that data
communication is
available (with the tool
in connection with PC)
Status of the tool
When the battery cartridge
is installed, the tool checks
for its LED indicator, light
and beeper.
When the battery cartridge
is installed with the switch
trigger pulled, the tool stops
to avoid unintentional start.
The tool setting has been
achieved and the tool has
stopped.
The tool has not completed
the tool setting because the
switch trigger has released
before reaching the set
values. Otherwise, the set-
tings of "Failure Criteria for
Phase" has been achieved.
The tool is in the intermitting
period configured by the
setting of "Shift to the next
Phase".
When the operator starts
to re-fasten an already-fas-
tened screw, the tool detect
it and stops.
The battery power became
low and it is time to replace
the battery cartridge.
The battery power is
almost used up and the tool
stopped.
The battery voltage dropped
abnormally for some reason,
and the tool stopped.
The motor or the controller
heated up abnormally and
the tool stopped.
The detection unit of the
motor fails to detect the
heat because the cord has
broken or other reasons.
Motor failure has been
detected. At this time, tool
does not work.
A maintenance time has
come according to your
preset number of screws
driven.
Data cannot be exchanged
between the tool and PC in
spite of the connection.
The tool is connected to PC
and data communication is
available.
Status of the LED indicator/beeper
LED indicator
Lights up first in green,
A series of very short
next red.
beeps
(And then the light
comes on.)
Blinks in red and green
A series of short beeps
alternatively.
Lights up in green for
approximately one
second.
Lights up in red.
A long beep
Lights up or blinks in
green (depending on
settings)
Lights up in red.
A long beep
Blinks in red slowly.
A series of long beeps
Lights up in red.
A long beep
Blinks in red and green
A series of short beeps
alternatively.
Blinks in red quickly.
A series of short beeps
Blinks in red quickly.
A series of short beeps
Blinks in red and green
A series of short beeps
alternatively.
Blinks in yellow.
Blinks in yellow.
Blinks in green.
9 ENGLISH
Action to be taken
Beeper
Release the switch
trigger.
Retighten the screw.
Replace the battery
with fully charged one.
Replace the battery
with fully charged one.
Replace the battery
with fully charged one.
Remove the battery
cartridge immediately
and cool the tool down.
Remove the battery
cartridge and cool
the tool down. If the
indicator does not stop,
ask your local Makita
Service Center for
repair.
Ask your local Makita
Service Center for
repair.
Reset the alarm
with the application
software.
Restart the application
software and re-con-
nect the USB cable.