7
Water to Water Heat Pump (WTW)
Outputs
Terminal
Name
Connector Item
block
OUT1
TBO.1 1-2 CNP1
OUT2
TBO.1 3-4
OUT3 TBO.1 5-6
OUT14
CNP4
OUT4
CN851
TBO.2 1-2
OUT5
TBO.2 2-3
OUT6
OUT7
OUT8
TBO.4 7-8
OUT9 TBO.4 5-6 CNIH
OUT11 TBO.3 5-6
OUT12 TBO.3 7-8
OUT13 TBO.4 3-4
OUT15 TBO.4 1-2
OUT10 TBO.3 1-2
OUT16 TBO.3 3-4
OUTA1 TBI.4 7-8
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1 For 2-zone temperature control.
*2 For 2-zone valve ON/OFF control.
N
L
N
L
N
L
1 2 3 4 5 6
TBO.1
OUT1 OUT2 OUT3
Wiring specification and local supply parts
Item
Name
External output
Outputs
function
wire
Note:
1. Do not connect multiple water circulation pumps directly to each output (OUT1, OUT2, and OUT3). In such a case,
connect them via (a) relay(s).
2. Do not connect water circulation pumps to both TBO.1 1-2 and CNP1 at the same time.
3. Connect an appropriate surge absorber to OUT10 (TBO.3 1-2) depending on the load at site.
4. Stranded wire should be processed with insulation-covered bar terminal (DIN46228-4 standard compatible type).
5. Use the same thing as the Signal input wire for OUTA1 wiring.
B-216
Water circulation pump 1 output (Space heating & DHW)
Water circulation pump 2 output (Space heating for Zone1)
Water circulation pump 3 output (Space heating for Zone2) *1
2-way valve 2b output *2
Water circulation pump 4 output (DHW)
3-way valve output
Mixing valve output *1
Immersion heater output
Error output
2-way valve 2a output *2
Comp ON signal
Boiler output
Heating thermo ON signal
Analog output (PICV Output)
N L L
N
TBO.2
1 2 3 4 5 6
TBO.3 1 2 3 4 5 6 7 8
Close Open
OUT5
Model and specifications
Use sheathed vinyl coated cord or cable.
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire: 0.25 mm² to 1.5 mm²
Solid wire: ø0.57 mm to ø1.2 mm
OFF
OFF
OFF
OFF
OFF
Heating DHW
Normal Error 230V AC 0.5A Max.
OFF
OFF
OFF
OFF
OFF
N L N L
TBO.4
OUT10 OUT16OUT11 OUT12
How to use TBO.1 to 4
Conductor
Outline view
Connect them using either way as shown above.
ON
Signal/Max current
ON
230V AC 0.6A Max.
ON
230V AC 1.0A Max.
ON
230V AC 1.0A Max.
ON
230V AC 0.4A Max.
Close
Stop
230V AC 0.1A Max.
Open
230V AC 0.1A Max.
(Relay)
ON
230V AC 0.1A Max.
ON
230V AC 0.5A Max.
non-voltage contact
ON
·220-240V AC (30V
DC)
0.5A or less
ON
·10mA 5V DC or
more
ON
0-10V DC 5mA max.
N
L
N
L
N
L
N L
1 2 3 4
5
6
7 8
OUT15
OUT13
OUT9
OUT8
Tool
Top view
<Figure 7.4.6>
Max. total
current
3.0A
1.3A
TBI.4 8 7
OUTA1
Tool
Conductor