PHILIPS 4000 and 3000
Page 5: High voltage loads test (Heater , Grinder ):
a) Heater (230V AC)
b) Grinder (320V DC)
The user can change the page by pressing the Z7 button.
Page 0 is accessible only entering Test Mode from power-off mode; at the start up all loads are
turned off.
Page 0 (FIRMWARE)
ERROR: If in machine model field is written "Unknow" and backlight of display is Yellow, check
the jumper in interface.
TEST MODE Level0
Pressing button Z7
TEST MODE Level1
Pressing button Z7
TEST MODE Level2
Pressing button Z7
TEST MODE Level3
Pressing button Z7
TEST MODE Level4
Pressing button Z7
TEST MODE Level5
Verify the firmware version
Firmware version on the display.
The machine model is shown ( FOCUS, CLASS or TOP).
The voltage of the main supply "230V"
The frequency of the main supply is shown (50 or 60 Hz)
The firmware version is the same as the label on MicroController
ERROR: The firmware version is different from the label on MicroController;
change the CPU_POWER Boards !
Press Z7 "
The machine passes to the Page 1 (KEYBOARD)
ERROR: The page does not change; Check the interface
board and the flat cable (JP21)
" to move to the next screen
05 SERVICE MODE
Pressing button Z7
2/18