Honeywell VISTA-250FBPT Installation And Setup Manual page 9

Commercial fire and burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-250FBPT:
Table of Contents

Advertisement

Program feature or option
1∗ 49 SUPPRESS TX SUPERV.
SOUND
1∗ 53 DOWNL OAD CAL L BACK
1∗ 57 ENABL E 5800 RF BUTTON
GL OBAL ARM
1∗ 58 ENABL E 5800 RF FORCE
ARM
1∗ 60 ZONE 5/AUDI O AL ARM
VER.
1∗ 72 PRI NTER ON-L I NE M ODE
1∗ 76 ACCESS REL AY #
(PARTI TI ON SPECI FI C)
1∗ 78 EXT. H OM E CONTROL EVT
1∗ 79 H OM E CONTROL EVENTS
1∗ 80 L OG-FAUL TS & RESTORES
2∗ 07 AUTO-DI SARM DEL AY
(PARTI TI ON SPECI FI C)
2∗ 18 ENABL E GOTO FOR
PARTI TI ON (PARTI TI ON
SPECI FI C)
2* 21 SUPERVI SI ON PUL SES
FOR COM MUNI CATI ONS
DEVI CE
2∗ 22 DI SPL AY OTH ER FI RE
AL ARM S (PARTI TI ON
SPECI FI C)
2∗ 23 DI SPL AY OTH ER BURG &
PANI C (I NCL UDI NG CO
AL ARM S) (PARTI TI ON
SPECI FI C)
2∗ 24 DI SPL AY TROUBL ES OF
OTH ER PARTI TI ONS
(PARTI TI ON SPECI FI C)
3∗ 01 EVENT DI SPL AY L OCK
3∗ 12 ZN TYPE 18 DEL AY USE
3∗ 13 "SUPV" ON OPEN AND
SH ORT (APPL I ES TO ZONE
TYPE 18
3∗ 14 W.F. AL ARM SI L ENCE
OPT.
3∗ 16 ZONE TYP 17/18 DL Y
3∗ 18 EXTENDED DL Y FOR TYP
17/18
3∗ 20 TRI G OUTS FUNC SEL
(ONL Y APPL I ES TO VI STA-
128FBPT)
3∗ 21 M AX ATEM PTS
Possible settings
Permitted in
UL864? Y/N
0 = disable
N
1 = enable
0 = callback requir ed
N
1 = no callback r equired
0 = disable
N
1 = enable
0 = disable
N
1 = enable
0 = disable
N
1 = enable
N
0 = disable
1 = enable
01-96 = relay number
N
00 = r elay not used.
N
1 = extended
0 = limited
N
0 = disable
1 = enable
N
0 = disable
1 = enable
00 = no delay.
N
01-14 t imes 4 minut es (04-56) delay.
15 = no auto disarming.
0 = disable
N
1 = enable
N
0 = disable
1 = enable
0 = disable
N
1 = enable
0 = disable
N
1 = enable
0 = disable
N
1 = enable
0 = disable
N
1 = enable
0 = disable
N
1 = enable
N
0 = Trouble on open/Supv on shor t
1 = Supv on open/Supv on shor t
0 = Silenced by User Code + OFF
N
1 = Silenced when zone r est or es
Ent er 01-15 t imes 2 seconds
N
Ent er 00 for no delay
0 = no ext ended delay
N
1 = mult iply delay by 4
0 = remote keypad sounder
N
1 = keyswitch L EDs
1-8
Y
9
Settings permitted in UL 864
M ust be set to "0" (disable).
M ust be set to "0" (callback
r equir ed).
M ust be set to "0" (disable).
M ust be set to "0" (disable).
M ust be set to "0" (disable).
Not used. M ust be set to "0".
M ust be set to "00" (relay not used)
for par t it ion 1.
Not used. M ust be set to "0".
Not used. M ust be set to "0" in each
ent ry.
Not used. M ust be set to "0".
M ust be set to "15" (no aut o
disar ming) for par t it ion 1.
M ust be set to "0" (disable) for
par t it ion 1.
Not Used. M ust be set to "00000"
(disable).
M ust be set to "0" (disable) for
par t it ion 1.
M ust be set to "0" (disable) for
par t it ion 1.
M ust be set to "0" (disable) for
par t it ion 1.
M ust be set to "1" (enable).
M ust be set to "0" (disable).
M ust be set to "0".
M ust be set to "0" (Silenced by User
Code + OFF).
M ust be set to 00 (no delay).
M ust be set to 0 (no extended delay).
M ust be set to 0 (remote keypad
sounder ).
M ust be set at 3, 4 or 5.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-128fbpt

Table of Contents