ASSEMBLY
CAUTION:
Always be sure that the tool is switched off and the
•
battery cartridge is removed before carrying out
any work on the tool.
Disposing of Dust
CAUTION:
Empty the cleaner before it becomes too full, or the
•
suction force weakens.
Be sure to empty out the dust inside the cleaner
•
itself. Failure to do so may cause the filter to be
clogged or the motor to be damaged.
1
009992
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
009993
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
NOTE:
Dust may spill out when capsule is opened, so be
•
sure to set a garbage bag beneath capsule.
1
009994
1. Suction inlet
2. Capsule
2
1. Capsule
2. Suction inlet
1
2
1. Prefilter
2. Capsule
2
Remove accumulated dust from inside of capsule and off
of prefilter.
1
009995
Twist prefilter in direction of arrow to unfasten securing
lip from cleaner unit and then pull off prefilter.
1
009996
Clean out fine dust from prefilter. Next, remove filter, and
lightly tap to dislodge dust.
Reassembly
1
009997
Put on filter until it is fully in position on the cleaner unit.
NOTE:
Make sure filter is put on straight without being
•
peeled back. If filter is put on incorrectly as shown
in diagram, dust will get into motor housing, and
cause motor failure.
1
010005
5
1. Prefilter
2
2. Securing lip
1. Prefilter
2. Filter
2
1. Prefilter
1. Filter