NEC Electra Elite IPK II Programming Manual page 371

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Item
No.
08
Routing When Destination Busy or No
Answer
This option lets you determine how the system
will handle an ANI/DNIS call if destination is
busy or does not answer.
09
Calling Number Address Length
When Item 1=0 (ANI/DNIS receive format is
address), use this option to specify the
address length. The choices are from 1 to 8
digits in length.
Feature Cross Reference
J
J
2 - 336
Name
Conditions
None
T1 Trunking (with ANI/DNIS Compatibility)
Tie Lines
Input Data
0
= Play Busy or
Ringback Tone to
Caller (Busy/
NoAns)
1
= Route Caller to
Ring Group
Specified in
Program 25-04
(Transfer)
1~8
Electra Elite IPK II
Default
COS 01~14
COS 15
0
0
7
7
Program 34 : Tie Line Setup
Related
Program
25-04
34-09-01