CONFIGURATION MODE

The configuration mode is used to set the RAK150VF2 to match
the heating/cooling system. The default setting of this thermostat
is for 2-stage cooling with a 3-stage heat pump system. For
an alternate configuration, see #7 in the Configuration Mode
Settings below.
To configure the RAK150VF2, perform the following steps:
1. Ensure thermostat is in OFF mode.
2. Remove the thermostat's front cover.
3. To enter the configuration mode, hold CONFIG for ~ 2 seconds.
4. Once in the configuration mode, press the
change settings within each screen.
- Press the FAN (right) button to advance to the next screen.
- Press the MODE (left) button to return to the previous screen.
NOTE: Hold CONFIG button for ~2 seconds to save changes
and exit configuration menu.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (°F or °C)—Choose Fahrenheit or Celsius.
- Press the
- Press the FAN (right) button to advance to the
next screen. NOTE: Default factory setting is
Fahrenheit.
2. Temperature Differential—Stage 1—(1–9°F) (.5-4.5°C)
Set the number of degrees between the "setpoint" temperature
and the "turn on" temperature for first stage.
- Press the
value.
- Press the FAN (right) button to advance to the next screen.
Note: Default factory setting is 1ºF /.5ºC.
3. Temperature Differential—Stage 2 (1–9°F) (.5-4.5°C)
Set the number of degrees between when stage 1 turns on
and stage 2 turns on.
- Press the
value.
- Press the FAN (right) button to advance to the next screen.
- Note: Default factory setting is 1°F/.5°C.
or
button to select.
or
button to set differential
or
button to set differential