The configuration mode is used to set the RAK148F2 and
RAK164F2 to match the heating/cooling system. These
thermostats function with up to 2-stage heat pump systems
(RAK148F2 only).
To configure the RAK148F2 and RAK164F2, perform the
following steps:
Note: Operation being set will blink in the display.
1. Slide the Function switch to the OFF position.
2. Remove the thermostat's front cover.
3. To enter the configuration mode, simultaneously hold
the LEFT and RIGHT buttons in for 6 seconds while the
thermostat is in OFF mode. (See diagram on page 3.)
4. Once in the configuration mode, press the
button to change settings within each screen.
- Press the RIGHT button to advance to the next screen.
- Press the LEFT button to return to the previous screen.
NOTE: To exit configuration mode at any time, slide the
Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
1. Temperature Scale (F or C)—Choose Fahrenheit or
Celsius.
Press the
to select.
Press the RIGHT button to advance to
the next screen.
NOTE: Default factory setting is Fahrenheit.
2. Temperature Differential—Stage 1—
(1–9°F) (1–5°C)
Set the number of degrees between the
"setpoint" temperature and the
"turn on" temperature for first stage.
Press the
Press the RIGHT button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage.
10

CONFIGURATION MODE

or
button
or
button to set differential value.
or