Video Recorder DIVAR AN 3000 and DIVAR AN 5000 families
In this release the PIC (Picture) recording mode is disabled because it
was not working as specified. This will be corrected in the next
firmware release.
1 DIVAR AN 3000/5000 firmware version 2.3.1 (date 2015-10-23)
File name: DVR.V2.3.1.R.20151023.bin
This release includes the following new features/improvement:
General improvements:
-
To ensure 100% reliable and viewable (recording of) video, we have added a detection
mechanism to detect bad camera signals which might give a problem displaying the video.
This feature will help the customer to identify weak signals and take appropriate actions to
resolve the problem. The administrator can disable this warning mechanism at any time in
the system events menu located under the advanced settings tab.
When a bad signal is detected, an error message will be shown in the top left of the
screen indicating: "Error displaying camera X, bad signal".
When this message is shown:
o Check the camera connections and replace/tighten the connections if necessary.
Make sure no ground loops are present
o Check the camera video signal and replace the camera if necessary
Added a setting to force a system to NTSC, PAL or auto-detect (default) to prevent the
-
system from accidently switching to a different mode in case of a bad camera signal.
HTTPS/SSL has been implemented in the unit to make the communication more secure and
-
to prevent 'man in the middle' attacks.
A menu item has been added to the quick menu to directly logout a unit
-
An option has been added to show/hide the timeline selection in playback
-
A new option has been added to completely covert cameras. This option can hide all
-
camera names, recording / alarm icons, etc. and will only show a black frame. This option
works together with the live viewing rights of a camera.
The account order of the login window can now be configured in the user account
-
configuration page.
New features are now also translated in different languages supported by this device
-
Improved snapshot functionality:
It is now possible to easily make snapshots from all cameos:
-
o Single live view and instant playback by selecting the snapshot button in the cameo
Document type
Release notes
Release #
SAP/Doc number
V2.3.1 (2015-10-23)
Release date
2015-10-28
Page 1 of 22

Advertisement

loading

Summary of Contents for Bosch DIVAR AN 3000

  • Page 1 DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) Video Recorder DIVAR AN 3000 and DIVAR AN 5000 families In this release the PIC (Picture) recording mode is disabled because it was not working as specified. This will be corrected in the next firmware release.
  • Page 2 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) o Multi-screen live view by selecting the snapshot button in the quick menu o Playback view by selecting the snapshot button in the button bar. In playback, the...
  • Page 3 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) o FTP Because a backup can drain system performance, always schedule a start time during a quiet period where features such as local playback/export are not required.
  • Page 4 This will be corrected in the next firmware release. Time line of recorded alarm video in the Bosch player is green instead of red when this is recorded via the Scheduled Backup feature.
  • Page 5 SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) Recommended BVC version: BVC v1.7.4 is recommended for this firmware release. Bosch strongly recommends upgrading to the latest firmware for the best possible functionality, compatibility and performance. Page 5 of 22...
  • Page 6: Update Procedure

    Release date 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) 2 Update procedure To update the DIVAR3000/5000 to the latest firmware, please refer to the Operator manual, section 7.5.4, or follow the instructions below: 1.
  • Page 7 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) 5. Select the Version menu (see below). 6. Update the current firmware as follows: a. Insert a USB stick with a preloaded update file into the USB connector on the front of the DVR.
  • Page 8 The ‘File Association’ setting in Archive player is disabled in this release. The Archive Player will not be downloaded from the DVR when archiving is performed via Web Client. Use the Archive Player available on the Bosch website (and on the product CD), or download it by performing a local archive.
  • Page 9 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) Second encoding stream will be configured automatically to accommodate the selected bandwidth limit. For example if bandwidth limit is set to 256 kbps than encoding settings of all cameras will be set to 64 kbps for the 2 stream to optimize viewing of four cameras.
  • Page 10 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) In the following Network screen, the bandwidth limits can be set to No (default), 256 Kbps, 512 Kbps, 1M, 2M, 5M or 10Mbps. This new feature supports full bandwidth control. This means that, when the bandwidth limitation is active, all DVR network communication outside the sub-net will be limited to the selected bandwidth setting.
  • Page 11 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) Playback in BVC During BVC playback under low bandwidth control, only I-Frames are streamed to save bandwidth. In full screen, an I-Frame will be streamed every second.
  • Page 12 Release date 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) Intuikey keyboard connection One Intuikey keyboard can communicate with a maximum 16 DIVAR 5000 units (not supported on the DIVAR 3000): Keyboard address must be set for every DIVAR 5000 First camera offset must be set for every DIVAR 5000.
  • Page 13 Release date 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) New keyboard adapter New RJ11 adapter with RJ11 adapter IN and OUT to loop-through the keyboard cable to multiple DIVAR 5000 recorders. New configuration Tool Separate Configuration Tool provided (see http://IPaddress/?config) –...
  • Page 14: Bug Fixes

    BVC 1.4 sr7 or higher requires firmware v1.3 on every DIVAR AN 3000/5000 o Older BVC versions are not supporting firmware v1.3 Warning window added in BVC 1.4 sr7 when connected to DIVAR AN 3000/5000 with older firmware than v1.3...
  • Page 15 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) GMT +4:30, GMT +5:45, GMT +6:30, GMT -4:30, and GMT -12:00 are removed from firmware, and common time zone names are added for appropriate time zone settings.
  • Page 16 2015-10-28 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) o There is a new ‘playback time’ field to quickly and accurately start playback at a given time o Playback settings (time/date/channel selection) can be modified while performing...
  • Page 17: Known Limitations

    DVD or a memory device instead of locking it on the DVR Some latency for PTZ cameras is shown using the Bosch Intui keyboard The ‘Monitor adjust’ feature does not fully adjust the margins over the whole screen on a monitor.
  • Page 18 Product Document type Release # SAP/Doc number DIVAR AN 3000/5000 Release notes V2.3.1 (2015-10-23) When exporting files to a DVD RW, the system will first format the DVD and then write the exported file to the disk. A warning is shown before the format process starts deleting all files on the disk The format button gives a ‘Format failed’...
  • Page 19 In previous firmware releases the max. number of remote client connections was limited to 4. Now this limitation is extended to 64, however more than 4 remote clients can lead to performance limitations. Therefore Bosch strongly advice not using more than 4 connections simultaneously.
  • Page 20 We recommend using BVC v1.7.2. release with the included ConfigManager for this. Bug fixes: Latency issues for PTZ cameras while using the Bosch Intui keyboard have been resolved. Hang in export menu due to the automatic file size calculation has been fixed. The size calculation is now done when pressing the add button instead.