8.11. Hal sensor U, Circulation
pump, Drain pump and
Separator.
8.11.1. Replacement of SF switch U (Hall
sensor U)
1. Follow the procedure for replacement of Controller(Power
side) (8.4.1), remove 3 connectors for the SF switch
U(Hall sensor U), Circulation pump and Drain pump from
the Controller (Power side).And remove 3 Clamping
bands fixing the lead wire, 1 Circulation pump connector,
2 Drain pump terminals and 1SF switch U(Hall sensor U)
fixing screw.

8.11.2. Replacement of Circulation pump

1. Tilt the Controller (Power side) down (*refer to the
Replacement of Damper (8.5.1)), and remove 2
Circulation pump fixing screws and the Separator side of
the Suction hose A.
8.11.3. Replacement of Drain pump and
Separetor After taking out
Separator Assembly (Separator +
Drain pump) from Base, remove
Drain pump from Separator.
1. Remove Service hose BU and Drain hose B from
Separator.
2. Remove Discharge hose A and Discharge hose C on the
Outer tub cover. ( both two hoses is connecting to
Circulation pump)
3. Remove 1 Separator fixing screw and take out the
Separator Assembly from Base.
4. Remove 3 Drain pump fixing screw and take out the Drain
pump from Separator.