Menu
Cold Temp Set
Hot Temp Set
Temp Display
UV Timer
F/C
Language
Flow Counter
Filters Timer
Filters Life
Energy Saving Sleep Mode
Default Set
Reset
WL500 Manual
PROGRAMING MENU AND SELECTIONS
Options
Brief Description
The cold temperature can be set between 3°C and 12°C or 37°F and 54°F,
3° ‐ 12°C
depending on which units are selected (°C or °F) in the F/C option.
37° ‐ 54°F
Recommended/Default Setting is 5°C/41°F.
The hot temperature can be set between 70°C and 95°C or 158°F and
70°C ‐ 95°C
203°F, depending on which units are selected (°C or °F) in the F/C option.
158°F ‐ 203°F
Recommended/Default Setting is 87°C/189°F.
Static
The display indicates the STATIC (SET POINT) temperature. Default
Ranging
The display indicates the ACTUAL tank temperature
The UV Lamp lights every time you take a drink of cold water, and stays on
3 minutes
for 3 minutes. Recommended/Default Setting is 3 minutes
The UV Lamp lights every time you take a drink of cold water, and stays on
10 minutes
for 10 minutes.
Constant
The UV Lamp stays on when power is on. Not Recommended
F
Temperatures are displayed in degrees Fahrenheit. Default is
C
Temperatures are displayed in degrees Celsius.
English
The display will read in English. Default is English
Spanish
The display will read in Spanish
French, Etc.
The display will read in French, and many others...
Liters
DO NOT USE. "NO WATER SUPPLY" Fault will occur. Use Filters Timer
(4000‐9000)
Instead.
Gallons
DO NOT USE. "NO WATER SUPPLY" Fault will occur. Use Filters Timer
(1000‐3000)
Instead.
Timer for Filters Life set at 3 months. Displays "Change Filters" after 3
3 months
months
Timer for Filters Life set at 6 months. Displays "Change Filters" after 6
6 months
months
Timer for Filters Life set at 9 months. Displays "Change Filters" after 9
9 months
months
None
Timer for Filters Life is turned off. Default is None
Indicates amount of water flowed(gal/liters) or days elapsed since last
00 DAYS
reset
Ensure Filters Timer is enabled and Filters Life indicates DAYS
On
Shuts heater down (hot water) if not used in 3 hours. – Default Sleep is ON
Off
Hot water remains powered indefinitely.
Defaults Display & Dispense Selection to Cold after 3 seconds.
Cold
Cold
Sparkling
Defaults Display & Dispense Selection to Sparkling after 3 seconds.
Resets the Filters Life to zero. Confirm by selecting Button 3 (Hot) to Save
OK?
and Exit. This resets the timer.
Page 23 Revision 4‐10‐2019
o
F
Default is