WaterLogic WL200 Installation Procedures Manual

WaterLogic WL200 Installation Procedures Manual

Hide thumbs Also See for WL200:

Advertisement

Quick Links

 
      DANGER!  ELECTRICAL SHOCK HAZARD.  
Only qualified personnel who have read and understand this entire manual should attempt to 
install, or service this unit, failure to do so could result in death or serious injury.  DO NOT plug 
into an electrical supply until specifically instructed.  
 
 
       WARNING!  ALWAYS SANITIZE BEFORE USE. 
 Sanitize before use to eliminate any potential microbiological contaminates.      
 
CAUTION!  DRIP TRAY DRAIN.  
If you intend to provide a drip tray drain for your customer, be aware that you will be called 
multiple times per month to service and unclog the tubing leading away from the drip tray to 
drain.  Users will clog the drain with paper clips, erasers, napkins, tea bags, gum, and various 
other intended items.  Waterlogic recommends you establish a minimum of weekly visits to 
the machine for cleaning of the drip tray drain. 
 
Materials Needed:  
 Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  
 Phillips Screwdriver   
 Temperature Gage 
 Water Pitcher or Container to collect water from the faucet 
 5 gallon container or drain basin 
 Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 
 ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings 
 TDS Meter and Test Strips for measuring chlorine ‐ Optional 
 
1. Unpack the Waterlogic WL200 Water Treatment System and check exterior for damage.
  
 
Sanitizing 
 
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved 
cleaner throughout the cold and sparkling water circuits.  Follow all instructions on the sanitizer 
and flush with fresh water through the faucet until odor and taste is acceptable. 
 
       WARNING!  USE PROPER PERSONAL PROTECTIVE EQUIPMENT 
Always ensure proper ventilation and use proper personal protective equipment such as gloves 
and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific 
requirements of each chemical product. Take all necessary precautions to prevent sanitizer 
from contacting eyes, clothing, and any other surfaces in could damage (carpets).   
 
2. Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½ 
cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) in the Sanitizing 
Cartridge.  Always ensure sanitizer is compatible with stainless steel and acetyl plastic. 
 
WL200 Manual 
PRE‐INSTALLATION PROCEDURES 
                                                                    Page 32 ‐ Revision: 4‐29‐2019 
 
 

Advertisement

loading

Summary of Contents for WaterLogic WL200

  • Page 1   Materials Needed:    Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear    Phillips Screwdriver     Temperature Gage   Water Pitcher or Container to collect water from the faucet   5 gallon container or drain basin   Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner   ¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings   TDS Meter and Test Strips for measuring chlorine ‐ Optional      1. Unpack the Waterlogic WL200 Water Treatment System and check exterior for damage.        Sanitizing    Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved  cleaner throughout the cold and sparkling water circuits.  Follow all instructions on the sanitizer  and flush with fresh water through the faucet until odor and taste is acceptable.           WARNING!  USE PROPER PERSONAL PROTECTIVE EQUIPMENT  Always ensure proper ventilation and use proper personal protective equipment such as gloves  and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific  requirements of each chemical product. Take all necessary precautions to prevent sanitizer  from contacting eyes, clothing, and any other surfaces in could damage (carpets).     ...
  • Page 2 3. Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of  unit.  Turn on water supply.    4. Connect power to WL200 Water Treatment System.  DO NOT TURN ON RED  POWER SWITCH AT THIS TIME O = OFF.       Fill the Cold Circuit with Sanitizer    5. Depress the main dispensing button on the front control panel until cold water/sanitizing solution  comes out the faucet.  NOTE:  Container and drain basin will be required to catch the water from  the faucet.      WARNING!  Use Personal Protective Equipment.  Gloves and Eye Protection Required.  The first  2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!     6. Turn off water supply and remove Sanitizing Cartridge from inlet water supply.  Reconnect water  supply to inlet bulkhead fitting.      Flush Filters          CAUTION!  FILTER FLUSH REQUIRED.    WL200 Water Treatment Systems are not supplied with filters.  Filters should be configured to  optimize your system.  Filters need to be configured and specified to do the job given the local  water conditions, usage, maintenance schedule, and placement restrictions.     In order for the filters to perform as represented and to provide the best quality water possible, it  is essential that filters be replaced periodically. The frequency of filter changes depends upon your  water quality and your water usage. For example, if there is a lot of sediment and/or particles in  your water, then you will have to change your filters more frequently than a location with little to  no sediment. Be sure to replace your filters whenever you notice a decline in the performance,  whether it is a drop in flow rate and/or pressure or an unusual taste in the water.    7. Flush thoroughly per filter manufacturers’ recommendation with fresh water to drain.  ...
  • Page 3 Flushing the Sanitizer from the Machine    10. Place a pitcher, catch basin, or other container under the faucet of the WL200 Water Treatment  System.    11. Flush the Cold Tank.  Run several gallons of water through the faucet by dispensing cold water to  dilute and remove the sanitizer from the cold circuit.  You can use chlorine test strips to evaluate  the water.     12. Once the sanitizer odor/taste has been flushed out of the cold side of the machine the  sanitization process for the Cold Circuit is now complete.           WL200 Manual                                                                      Page 34 ‐ Revision: 4‐29‐2019 ...
  • Page 4 WL200 COUNTER TOP DRAINING INSTRUCTIONS    Drain the WL200 Water Treatment System for transportation.           WARNING!  STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE REUSE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbial growth).        Turn off Water Supply and Bleed Water Pressure    1. Isolate the WL200 Water Treatment System from feed  water by turning off the supply.     2. Dispense cold still water to relieve any pressure built up in  the system.    3. Remove the water supply line from the inlet line bulkhead  fitting at back of the WL200 Water Treatment System.  Water Supply Line     4. Depress Cold Water Dispense Button until all Cold Water has drained from the WL200 Water  Treatment System.    5. Depress Hot Water Dispense Button until all Hot Water has drained from the WL200 Water  Treatment Machine.        WL200 Manual                                                                      Page 35 ‐ Revision: 4‐29‐2019 ...
  • Page 5 WL200 TOWER DRAINING INSTRUCTIONS    Draining Notes    Drain the WL200 Water Treatment System for transportation.           WARNING!  STORE AND TRANSPORT UNIT EMPTY.   ALWAYS SANITIZE BEFORE USE.  The unit must be completely drained before storing to avoid stagnation and reduce  microbiological contamination (potential bacterial growth).  Always sanitize before use to  eliminate any potential microbiological contaminates.     Disable Cold Tanks    1. Turn off the Red Power Switch to disable the compressor. O = OFF    Turn off Water Supply and Bleed Water Pressure    2. Isolate the unit from feed water by turning off the supply.   3. Dispense cold still water to relieve any pressure built up in the system.  4. Remove the water supply line from the inlet line bulkhead fitting at back of machine.  5. Install dust cap or plug into water supply line bulkhead fitting.    Drain the Cold Water Tank and Circuit    6. Remove lower front panel to access tank feed lines.                                 7. Disconnect tank line feed line from cold inlet solenoid to  drain into basin or catch.   ...
  • Page 6: Installation Procedures

      WARNING!  USE ONLY Waterlogic SUPPLIED POWER CORD.  Locate system within 5 feet of  power supply.  Never use an extension cord or adapter.  Do not use a damaged power cord or  plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do not, under any  circumstances, remove ground prong or alter the power cord.  Never pull the power plug from the  outlet with a wet hand or allow the plug to get wet.  Failure to use the supplied power cord will  void UL Certification and Warranty.      CAUTION!  INDOOR USE ONLY.   Never expose to direct sunlight, heat sources, or ambient air  temperature above 37°C (100°F) or below 2°C (35°F).  Install indoors and keep unit away from  excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate clearance  around the unit to allow refrigeration system condenser to dissipate heat.  Warmer environments  require more clearance around the unit.  Minimum clearance around all surfaces of the machine is  2‐inches.  Installs where the ambient temperature exceeds 26.7°C (80°F), require a minimum of 4‐ inches clearance for proper heat dissipation and efficient operation.       CAUTION!  USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or  damage caused by excessive water pressure.  Operating pressure must be 40 psi to 60 psi.  Be  aware any of potential pressure surges caused by building/municipal pumping stations.      CAUTION!  USE UV STABILIZED SUPPLY LINES.  Feed the unit with a potable ambient or cold  water supply only.  Feed water over 37°C (100°F) can damage the treatment components.  Water  block devices and external leak detectors are strongly recommended. Locate the unit as close to  the water supply and the electrical connections as possible.             WARNING!  STORE AND TRANSPORT UNIT EMPTY.   ALWAYS SANITIZE BEFORE USE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any  potential microbiological contaminates     Pre‐installation and sanitization procedures as prescribed in this manual must be performed before  installing the WL200 Water Treatment System.    Always install indoors and place the Waterlogic WL200 Water Treatment System on a firm, flat and  stable surface.      WL200 Manual                                                                      Page 37 ‐ Revision: 4‐29‐2019 ...
  • Page 7   1. Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.   Waterlogic requires the use of a water pressure regulator.  Water feed pressure must be  between 40‐60 psi.   Turn on the water supply and check for leaks.           2. Check to ensure that the Red Power Switch is off.   O=OFF            3. Connect the power cord to the back of the Waterlogic WL200 Water Treatment System and to a  120 Volt supply.    4. Fill the Cold Tank.  Hold a container under the dispensing faucet, press and hold the main  dispensing button until a continuous flow of water is obtained.  Once a continuous flow is  obtained, release the dispensing button.  Cold tank is now full.      5. Move the Waterlogic WL200 Water Treatment System into its final operating position.  Be sure  that a minimum of 2” clearance is maintained around both the sides and the back of the unit.   This is important to allow proper airflow and heat exchange of refrigeration system.     6. Level unit using the adjustable feet to level if necessary.  Never install on incline.    7. Turn the Red Power Switch on.  I=ON.             ...