Download Print this page
Honeywell GENT VIG-BNG Installation And Configuration

Honeywell GENT VIG-BNG Installation And Configuration

Vigilon bacnet gateway

Advertisement

Quick Links

Installation and Configuration
Vigilon BACnet Gateway
(VIG-BNG & VIG-BNG-RW)
The Vigilon BACnet Gateway kit consists of:
HS-GW-EMPCA
REVB
PROGRAM
PWR
WDT
PWR
NC
C
NO
1 x BACnet Gateway
J7
J6
Board
J8 ENET
ACTIVE
NFN B
DATA
LINK
USB B
J14
J13
USB A
4 x Board Spacers
(for BACnet Board)
1 x Cable assembly
RS232
How to install BACnet Gateway kit into a Vigilon Compact Network Node
To install the kit inside a Vigilon Network node follow illustrated steps
Previous
Next xt
EN54
Previous
Next
Vigilon Network
Domain 1
Open doors
Vigilon Compact Network Node
Replace fuse
FS3 200mA
FS3 1A
4188-970_issue 2_08/11_BACnet
The Vigilon BACnet Gateway (VIG-BNG & VIG-BNG-RW#) provides
an interface between a computer network and GENT EN54 Vigilon fire
detection and alarm system, using BACnet communication protocol.
General Data
Supports
Up to 15 GENT EN54 Vigilon panels/nodes in a network
with up to 15000 object counts, ie loop devices
Conforms
BACnet standard Annex J for IP and support Device
objects, Life Safety Points/Zones and Multistate
inputs/outputs, Multistate values#
Power
24Vdc @ 360mA
o
Operating
0
C to 49
temperature
93% humidity non-condensing at 30
# Binary values on RW version only for Command build
BACnet protocol: see
GENT protocol: Vigilon 3217 protocol
EBI BACnet
Card
Up to 15 panels/nodes
KEYBOARD INDICATORS
Previous
Next
AND DISPLAY
WARNING
REMOVAL OF COVER
EXPOSES HIGH VOLTAGE
Node 1
24V
0V
B
A
TX1 RX1
0V
TX2 RX2
PB15
PB6
NC
C
NO
24V
FS3
J7
J6
J8 ENET
DATA
USB B
LINK
J14
o
C
www.bacnet.org
(Standard 135-2004)
1 x Board Carrier
2 x Board Spacers
(for Board Carrier)
1 x 1A fuse
u
x
to
24V
0V
B
A
TX1 RX1 0V
TX2 RX2
L1 0V L2 0V
PB15
PB6
PB14
24V
FS3 200mA
P1
CARD 2
FIRMWARE BACKUP
Network
Card 2
IC3
IC16
SW2
MODE
P16
EBI BACnet
Card
HS-GW-EMPCA
REVB
PROGRAM
PWR
WDT
PWR
Card Carrier
BACnet
ACTIVE
Card
NFN B
J13
USB A
by Honeywell
o
C
1 x Surge Protector
for RJ45
1 x Spare parts
1 x Red and black
wires for power supply
.
Master Control
Power Supply
Board (MCB)
Unit (PSU)
N E
L
NC C NO NC C NO NC C NO
L1 0V L2 0V
0V MIPNC C NO
MA1+ MA1- MA2+ MA2-
P2
PB10
PB11
PB7
PB9
PB8
DANGER
FS3 3.15A(T)
Mains fuse
N
L
MA1 - FS1 250mA
MA2 - FS2 250mA
P2
CARD 1
Warning
Removal of
cover exposes
live parts
DANGER
POWER
SUPPLY
P12
P1
P3
SW1
P7
BATT3
RESET
BAT1
1

Advertisement

loading

Summary of Contents for Honeywell GENT VIG-BNG

  • Page 1 Installation and Configuration Vigilon BACnet Gateway by Honeywell (VIG-BNG & VIG-BNG-RW) The Vigilon BACnet Gateway (VIG-BNG & VIG-BNG-RW#) provides an interface between a computer network and GENT EN54 Vigilon fire detection and alarm system, using BACnet communication protocol. General Data...
  • Page 2 Installation and Configuration Vigilon BACnet Gateway How to wire the BACnet Gateway board into the Vigilon Compact Network Node The BACnet Gateway connects to GENT EN54 Vigilon Fire Alarm network via RS232 serial port and connects to BACnet front end via RJ45 Ethernet connector. To wire the BACnet Gateway board inside a Vigilon Network node follow illustrated steps 24V power supply Ethernet RJ45...
  • Page 3 Vigilon BACnet Gateway Installation and Configuration Connect the BACnet Gateway to a switch/hub. Change the IP address of the network adaptor on you PC to be the same as the Gateway Routing IP address (10.1.6.2). Launch the GENT Configuration tool and make the necessary changes to the GENTGW.ini file. Select the required time zone country / location.
  • Page 4 Do not burn. Gent by Honeywell reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions of changes.

This manual is also suitable for:

Gent vig-bng-rwGent vigilon vig-bngGent vigilon vig-bng-rw