[3] DISASSEMBLY/ASSEMBLY
[3]-4. Replacing Blade case
(1) Disassemble Safety cover as drawn in Fig. 7.
(2) Disassemble Bearing box section as drawn in Fig. 8.
(3) Disassemble Motor section from Blade case as drawn in Fig. 12.
(4) Disassemble Base as drawn in Figs. 3 and 4. Blade case can be replaced.
[3]-5. Adjustment
(1) Set the machine as follows.
* Bevel angle: 90°
* Cutting depth: maximum depth
And tighten M6x21 Thumb screw and Lever plate to keep the above conditions.
(2) Adjust accuracy of 90° of Base to Saw blade as drawn in Fig. 13.
(3) Adjust the base in parallel to Saw blade as drawn in Fig. 14.
Fig. 13
1.Insert 1R048 into the clearance between
Blade case and Lever 37 so as to hold
Safety cover and ensure the access to Blade.
Note: Make sure that Safety cover does not
move before doing step 2.
Blade case
Fig. 14
1. Unlock the cord guard side of Base from Blade case by
loosening M4x8 Pan head screw slightly.
2. Move the cord guard side of Base by hand in the direction
of yellow arrows until the distance A is equal to B.
3. After finishing the adjustment, tighten M4x8 Pan head
screw firmly.
2. Apply the block of 1R208 to Base and adjust accuracy of
Safety cover
Lever 37
1R048
Note: Do not turn this M5x8 Hex socket set screw. This works as
90° by turning M5x8 Hex socket set screw with Hex wrench 2.5
until the ruler plate of 1R208 touches Saw blade.
Ruler plate of 1R208
Block of 1R208
1R208
M5x8 Hex socket head set screw
a stopper for 6-7 Shoulder pin (hinge of Angular guide).
Cord guard side of Base
A
B
Saw blade
Hex wrench 2.5
M4x8 Pan head screw (2 pcs.)
P 9/ 11