  • Page 1 3G Industrial Pro User’s Guide rev. 1.1 02/2013...
  • Page 3 3G Industrial PRO User’s Manual We, Digicom S.p.A. registered office at: Via Volta 39 – 21010 Cardano al Campo (Varese – Italy) declare under our sole responsability that the product with name 3G Industrial Pro Type: HSPA Router, Category: Device for the Information Technology satisfies the basic requirement of the below indicated Directive: 1999/5/EC 9th March 1999, R&TTE (concerning radio equipment and telecommunication terminal equipment...
  • Page 4 3G Industrial PRO User’s Manual www.digicom.it...
  • Page 5: Table Of Contents

    3G Industrial PRO User’s Manual www.digicom.it Contents Contents ......................................3 Introduction to 3G Industrial PRO ............................... 4 1.1Overview ..................................4 1.2Package Checklist ................................4 1.3Product Features ................................4 1.3.1 Interfaces ................................4 1.3.2 Functions ................................5 1.3.3 Environmental Limits ............................6 1.3.4 Power Requirements ............................
  • Page 6: Introduction To 3G Industrial Pro

    Introduction to 3G Industrial PRO 1.1 Overview 3G Industrial PRO grade routers provide users with stable and high speed connection between remote devices and customer’s center via 2.5G/3G networks. They allow wide voltage power supply (9-48V DC), large range operating temperature from -25°C to 70°C (-10 ~ 158F)/ humidity: 95% RH, and fully satisfy various EMC verifications, which ensure stability and...
  • Page 7: Functions

    3G Industrial PRO User’s Manual www.digicom.it Number of Ports: 1 Ethernet: 10/100 Mbps, RJ45 connector, Auto MDI/MDIX Magnetic Isolation Protection: 1.5 KV built-in Serial A. Serial Type: RS232/485 B. Data bit: 5/6/7/8 C. Stop bit: 1/2 D. Check bit: N/O/D E.
  • Page 8: Environmental Limits

    3G Industrial PRO User’s Manual www.digicom.it Support VRRP protocols, realizing immediate link backup DNS Forwarding Support DNS Forwarding, support DNS record Network tools Support Ping, Trace Route and Telnet Wakeup Over LAN (WOL) Support Wakeup over LAN, to wakeup industrial PC over Eth. after receives SMS.
  • Page 9: Quick Installation Guide

    2.1 Typical Application 2.2 Panel Layout 3G Industrial PRO can be used to connect your device (with RS232/485/Ethernet Interface) to internet via GPRS/HSUPA cellular. Meanwhile, to ensure the security and access, 3G Industrial PRO support VPN, enabling remote access and secure data transmission through internet.
  • Page 10 3G Industrial PRO User’s Manual www.digicom.it Description of LED Legend: On-- Off-- Blink-- Power on Start to run firmware Begin dial to Internet Connect to internet Upgrading firmware Restore factory default Signal Status LED Description ----- Signal: 1-9 (bad signal level, route cannot work, please check the antenna and local signal level)
  • Page 11: Quick Connection To Internet

    Link the power supply in the product package with Industrial PRO, watch where the Industrial PRO Power LED on the panel is light up. If not, please connect with Digicom for technical supports. You can configure 3G INDUSTRIAL after the Power LED lights up.
  • Page 12 3G Industrial PRO User’s Manual www.digicom.it 3) Click “Properties”, enter “Local Area Connection Properties” screen Choose “Internet Protocol (TCP/IP)”, click “properties” button, ensure your PC can obtain IP and DNS address automatically. (Or you can set your PC in the subnet: 192.168.2.0/24, for example, set IP: 192.168.2.10, Net Mask:...
  • Page 13 3G Industrial PRO User’s Manual www.digicom.it Click “OK”, Industrial PRO will allocate an IP address: 192.168.2.X, and a gateway: 192.168.2.1(the default address of 3G INDUSTRIAL). After configure TCP/IP protocols, you can use ping command to check whether the link between PC and Router is built correctly.
  • Page 14: Start To Configure Your Industrial Router (Optional)

    3G Industrial PRO User’s Manual www.digicom.it If the screen shows: Then the link between the PC and Router is correct connected. Else if it shows: Then the connection seems not build, and you need to check thoroughly following the former instructions.
  • Page 15: Connect Industrial Router With Internet

    3G Industrial PRO User’s Manual www.digicom.it Click “Network”=>“LAN”, change the IP address to 192.168.1.254: 3) Click “Apply”, then you will see: Now the IP address of 3G INDUSTRIAL has been reset, and in order to enter the configuration web, you need set your PC in the same subnet, for example: 192.168.1.10/24 then input the changed IP address (192.168.1.254) in your IE...
  • Page 16 3G Industrial PRO User’s Manual www.digicom.it Please check the APN, Dialup Number, Username and Password: Dialup Number, Username and Password are provided by local mobile operator. You can contact them for more details. The following example shows parameters provided by Italian operators: TIM: ibox.tim.it, VODAFONE : web.omnitel.it, WIND: internet.wind, TRE: tre.it...
  • Page 17: Quick Ipsec Vpn Configuration

    3G Industrial PRO User’s Manual www.digicom.it 2.4 Quick IPSec VPN Configuration If you need to build a VPN tunnel to realize access to your PLC far away through internet or you need ensure the security by using VPN. Here’s a quick configuration guide of IPSec for Industrial Router Series.
  • Page 18 3G Industrial PRO User’s Manual www.digicom.it Basic Parameters: set basic parameters of IPSec tunnel. Tunnel Name: name IPSec tunnel, the default is IPSec_tunnel_1. Destination Address: set to VPN server IP/domain, e.g.: the domain provided by GJJ is gjj-ovdp.3322.org. Startup Modes: select Auto Activated.
  • Page 19: Reset To Factory Defaults

    3G Industrial PRO User’s Manual www.digicom.it You can click “Show Detail Status” to observe the specific connection details, or click “Add” to add a new tunnel. Now you succeed to build a high-security IPSec tunnel, here’s an example: We set an IPSec Tunnel from subnet: 192.168.220.0/24 to subnet: 192.168.123.0/24, when it succeeds, the web will show: And the PC in IPSec client subnet can get access to the server’s subnet.
  • Page 20: Web Method

    3G Industrial PRO User’s Manual www.digicom.it 3) After a few seconds, the ERROR LED then turns off, now push RESET button again: 4) Then you will see ERROR and STATUS blinking, which means reset to factory defaults successfully! Factory default settings: IP: 192.168.2.1...
  • Page 21: Advanced Configuration

    3G Industrial PRO User’s Manual www.digicom.it Advanced Configuration Configuration on Web Industrial PRO must be correctly configured before use. This Chapter will show you how to configure via Web. 3.1.1 Preparation Firstly, connect your devices with 3G INDUSTRIAL by cable or HUB (switch), then set the IP of PC and 3G INDUSTRIAL in the same subnet, for example: Set PC IP to 192.168.2.50, net mask: 255.255.255.0, gateway (default IP of...
  • Page 22: System

    3G Industrial PRO User’s Manual www.digicom.it Click “Login” to enter configure web: 3.1.2 System System settings include the 9 settings: Basic Setup, Time, Serial Port, Admin Access, System Log, Config Management, Update, Reboot and Logout. (1) Basic Setup Parameters Name...
  • Page 23 3G Industrial PRO User’s Manual www.digicom.it (2) Time Name Description Default Router Time Display router time 1970-1-1 8:00:00 PC Time Display PC time (or the time of device linked with router) Time Zone Set time zone Custom Custom TZ string...
  • Page 24 3G Industrial PRO User’s Manual www.digicom.it (4) Admin Access Name Description Default Username/Password Username Username for configuration web login Old Password To change the password, you need to input the old one 123456 New Password Input new password Confirm New Password...
  • Page 25 3G Industrial PRO User’s Manual www.digicom.it (5) System Log Name Description Default Log to Remote System Enable remote log server Disable IP address/Port (UDP) Set the IP and Port of remote log server Port: 514 (6) Config Management Name Description...
  • Page 26 3G Industrial PRO User’s Manual www.digicom.it Click “update”, and then click “sure” to begin update as it shows below. Upgrade firmware succeed, and click “reboot” to restart 3G INDUSTRIAL. (8) Reboot If you need to reboot system, please click ”System”=>”Reboot”, Then click ”OK” to restart system.
  • Page 27: Network

    3G Industrial PRO User’s Manual www.digicom.it 3.1.3 Network Network settings include configurations of Dialup, LAN, DNS, DDNS, Static Route, and etc. (1) Dialup Name Description Default Enable Enable PPP dialup Enable Time Schedule Set time for online and offline SHARED Enabled—device linked with Router Can access to internet.
  • Page 28 3G Industrial PRO User’s Manual www.digicom.it Name Description Default Password Dialup parameters provided by Local ISP “gprs” or ”CDMA” Primary Profile Retries After retries and dialup still failed, router will try backup dialup parameters (if you (always main have set two IPSec tunnels and one as backup, router will also stop the main one and parameters and never use try another, more details please see at “VPN”...
  • Page 29 3G Industrial PRO User’s Manual www.digicom.it Description Describe configuration Blank This page is to set the type of WAN port: Name Description Default Type Static IP; Disabled Dynamic Address(DHCP); ADSL Dialup(PPPoE); Disabled Attention: There can only be one WAN type at one time, enabling one type WAN will disabled another.
  • Page 30 3G Industrial PRO User’s Manual www.digicom.it Description Describe the settings Blank WAN—Dynamic Address (DHCP) Name Description Default Type Dynamic Address (DHCP) SHARED Enabled—the local device linked with Router can get access to Enable internet. Disable—the local device can’t get access to internet via Router.
  • Page 31 Name Description Default MAC Address The MAC address in LAN 00:10:A1:86:95:02 (Provided by Digicom) , for manufactures IP Address Set IP Address in LAN 192.168.2.1 (If Changed, you need to input the new address for entering the configuration web) Net Mask Set Net Mask of LAN 255.255.255.0...
  • Page 32 3G Industrial PRO User’s Manual www.digicom.it Detection Host Set Detection Host Address 0.0.0.0 WOL MAC Address Set the MAC of PC in the LAN of router, for Wakeup Blank Over LAN (WOL) function, you should also set “Networks” “Dialup” and change dialup mode into “Trigger by SMS”.
  • Page 33 3G Industrial PRO User’s Manual www.digicom.it DDNS (Dynamic DNS) Name Description Default Current Address Show the current IP address Blank Service Type Select DDNS Provider Disabled Name Description Default Service Type DynDNS - Dynamic http://www.dyndns.com/ Username Registered username for DDNS...
  • Page 34: Service

    3G Industrial PRO User’s Manual www.digicom.it 3.1.4 Service Service settings include DHCP Service, DNS Forwarding, VRRP and other related parameters. DHCP Service Name Description Default Enable DHCP Click to enable DHCP Enable IP Pool Starting Address Set the starting IP address of DHCP pool 192.168.2.2...
  • Page 35 3G Industrial PRO User’s Manual www.digicom.it DHCP Relay This function can realize DHCP relay and send relay packages to LAN interface of router. Name Description Default Enable DHCP Relay Click to enable DHCP Relay Enable (after enable DHCP) DHCP Server Set the DHCP Server’s address, always you need...
  • Page 36 3G Industrial PRO User’s Manual www.digicom.it (5) Device Manager Name Description Default Mode Disabled/Only SMS/SMS+IP Disable Name Description Default Mode Only SMS Query SMS Interval Set how long to check SMS 24 hours Trust Phone List Add trust Cell Phone List...
  • Page 37 3G Industrial PRO User’s Manual www.digicom.it Heartbeat Interval Set interval of heartbeat Packet Receiving Timeout Set packet receiving timeout Packet Transmit Retries Set packet transmit reties Query SMS Interval Set how long to check SMS Trust phone list Set trust cell phone list...
  • Page 38: Firewall

    3G Industrial PRO User’s Manual www.digicom.it SMS Access Control Default Policy Block or Accept control SMS from certain Phone Block Phone List Include phone numbers accepted or blocked to send SMS to router Notice: before using this function, please notice you have a SIM card with SMS function in the router, else, please contact local mobile operator.
  • Page 39 3G Industrial PRO User’s Manual www.digicom.it (2) Filtering Name Description Default Enable Click to enable filtering Blank Protocol Optional among TCP/UDP/ICMP Source IP address Set Source IP address Blank Source Port Set Source Port Blank Destination IP Set destination IP...
  • Page 40 3G Industrial PRO User’s Manual www.digicom.it (4) Virtual IP Mapping An internal PC’s IP can match to a virtual IP, and external network can access to internal PC via this virtual IP address. Name Description Default Virtual IP for Router...
  • Page 41: Qos

    3G Industrial PRO User’s Manual www.digicom.it 3.1.6 QoS Name Description Default Enable Click to enable Disable Outbound Limit Max Set the limit speed of out- bound 100000kbit/s Bandwidth bandwidth Inbound Limit Max Set the limit speed of inbound bandwidth 100000kbit/s Bandwidth 3.1.7 VPN...
  • Page 42 3G Industrial PRO User’s Manual www.digicom.it IPSec Tunnels Click “Add” and enter the configuration web: Name Description Default Show Advanced Options Click to enable advanced options Disable...
  • Page 43 3G Industrial PRO User’s Manual www.digicom.it Basic Parameters Tunnel Name To name the tunnel IPSec_tunnel_1 Destination Address Set the destination address of IPSec VPN Server Blank Startup Mode Auto Activate/Trigged by Data/Passive/Manually Activated Enable Negotiation Mode Optional: Main Mode or...
  • Page 44 3G Industrial PRO User’s Manual www.digicom.it GRE Tunnels GRE Tunnels Name Description Default Enable Click Enable Enable Tunnel Name Set GRE Tunnel Name tun0 Local Virtual IP Set Local Virtual IP 0.0.0.0 Remote Address Set Remote Address 0.0.0.0 Remote Virtual IP Set Remote Virtual IP 0.0.0.0...
  • Page 45 3G Industrial PRO User’s Manual www.digicom.it Name Description Default Enable Click Enable Enable Tunnel Name Set Tunnel Name L2TP_TUNNEL_1 L2TP Server SetL2TP Server Address Blank Username Set Server Username Blank Password Set Server Password Blank Server Name Set Server Name...
  • Page 46: Tools

    3G Industrial PRO User’s Manual www.digicom.it Name Description Default Enable Click Enable Enable Tunnel Name Set Tunnel Name PPTP_TUNNEL_1 PPTP Server Set PPTP Server Address Blank Username Set Server Username Blank Password Set Server’s Password Blank Startup Mode: Startup Modes: Auto Activated,...
  • Page 47: Status

    3G Industrial PRO User’s Manual www.digicom.it Trace Route Name Description Default Host Destination for Trace Route Blank Max Hops Set Max Hops Time Out Set Time Out 3 sec Protocol Optional: ICMP/UDP Expert Options Advanced parameters Blank (3) Link Speed Test Test link speed via unload or download 3.1.9 Status...
  • Page 48 3G Industrial PRO User’s Manual www.digicom.it Modem Status This page shows the status of Modem, including the signal level. (3) Network Connections This page shows the network connections via WAN or LAN (4) Route Table This page shows the route table of 3G INDUSTRIAL.
  • Page 49: Support

    For some situation when there’re some problems that can’t be diagnosed at the moment, you’ll be asked to provide the diagnose log to Digicom engineers, you can click “Download System Diagnosing Data” then send the diagnose log to us. Support In case you have problems with the installation and use, please address them to us by e-mail: support@digicom.it...
  • Page 50 Italy 21010 Cardano al Campo VA via Alessandro Volta 39 http://www.digicom.it...