System Description and Installation
Manual
HS- -600
High Speed Data System
This document contains technical data and is subject to U.S. export regulations.
These commodities, technology, or software were exported from the United States in accordance with the
export administration regulations. Diversion contrary to U.S. law is prohibited.
23- -20- -31
Title Page T--1
Pub. No. A15--5111--006
Printed in U.S.A.
30 May 2002

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell HS-600

  • Page 1 Honeywell Aerospace Electronic Systems CES- -Phoenix P.O. Box 21111 Phoenix, Arizona 85036-1111 U.S.A. System Description and Installation Manual HS- -600 High Speed Data System This document contains technical data and is subject to U.S. export regulations. These commodities, technology, or software were exported from the United States in accordance with the export administration regulations.
  • Page 2 (b) (4) of 5 USC 552 and the prohibitions of 18 USC 1905. S2002 Honeywell is a U.S. registered trademark of Honeywell. All other marks are owned by their respective companies. 23- -20- -31 Title Page T--2...
  • Page 3 FOR HONEYWELL USE ONLY REPORT OF POSSIBLE DATA ERROR CONTROL NO. DATE RECEIVED To help us improve the quality of our publication, Honeywell encourages any report of a possible data error. PUBLICATION INFORMATION Volume No. Publication Latest Issue Date A15- -5111- -006...
  • Page 4 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS PERMIT NO. 3532, PHOENIX, AZ POSTAGE WILL BE PAID BY ADDRESSEE Honeywell Aerospace Electronic Systems CES--Phoenix P.O. Box 21111 Phoenix, Arizona 85036-1111 U.S.A. ATTN: Technical Publications...
  • Page 5 FOR HONEYWELL USE ONLY CUSTOMER RESPONSE CONTROL NO. DATE RECEIVED To help us improve the quality of our publications, Honeywell encourages readers to provide input to the customer- -satisfaction survey below. We welcome all comments and recommendations. PUBLICATION INFORMATION Volume No.
  • Page 6 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS PERMIT NO. 3532, PHOENIX, AZ POSTAGE WILL BE PAID BY ADDRESSEE Honeywell Aerospace Electronic Systems CES--Phoenix P.O. Box 21111 Phoenix, Arizona 85036-1111 U.S.A. ATTN: Technical Publications...
  • Page 7 For each revision, put the revised pages in your manual and discard the superseded pages. Write the revision number and date, date put in manual, and the incorporator’s initials in the applicable columns on the Record of Revisions. The initial H shows Honeywell is the incorporator. Revision...
  • Page 8 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page RR--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 9 Manual By * from Manual By * * The initial H in this column shows Honeywell has done this task. 23- -20- -31 Page RTR--1 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 10 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page RTR--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 11 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SERVICE BULLETIN LIST Identified Date Included Service Bulletin Description in this Manual 23- -20- -31 Page SBL--1 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 12 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page SBL--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 13 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System LIST OF EFFECTIVE PAGES Subheading and Page Date Subheading and Page Date 1--4 30 May 2002 Title 1--5 30 May 2002 T--1 30 May 2002 1--6 30 May 2002 T--2 30 May 2002 1--7 30 May 2002...
  • Page 14 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Subheading and Page Date Subheading and Page Date B--4 30 May 2002 Installation Check B--5 30 May 2002 4--1 30 May 2002 B--6 30 May 2002 4--2 30 May 2002 B--7 30 May 2002 4--3...
  • Page 16 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System TABLE OF CONTENTS Subject Page INTRODUCTION ............INTRO- -1 Proprietary, Export, and Precautionary Data .
  • Page 17 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System B. High Speed Combiner Assembly ........2--1 C.
  • Page 18: Table Of Contents

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System D. Typical Maintenance Port Start--Up Information ......5--3 E.
  • Page 19 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System List of Illustrations Figure Page Figure 1-1. High Speed Data System Block Diagram ..... . 1--1 Figure 1-2.
  • Page 20 ......1--6 Table 1-11. Components/Parts Not Supplied by Honeywell ....1--6 Table 1-12.
  • Page 21 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page TC--6 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 23 (b) (4) of 5 USC 552 and the prohibitions of 18 USC 1905. Copyright 2002 Honeywell. All Rights Reserved. (3) Honeywell is a U.S. registered trademark of Honeywell. All other marks are owned by their respective companies.
  • Page 24: Table Intro--1. Related Publications

    Description, Installation, and Maintenance Manual MCS--4000/7000 Multi--Channel SATCOM System Description, A15--5111--001 Installation, and Maintenance Manual NOTES: You can order a Honeywell publication from Honeywell as follows: Telephone No.: (602) 436--6900 Fax No.: (602) 436--1588 E--mail: cas--publications--distribution@honeywell.com Page INTRO--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 25 ANSI/IEEE Std 260. C. Acronyms and Abbreviations (1) The acronyms and abbreviations that follow help the reader identify terms and definitions used by Honeywell. (2) The letter symbols for units of measurement are the same as shown in ANSI/IEEE Std 260.
  • Page 26 3. Customer Assistance A. Who to Contact (1) For assistance with installation, operation, or maintenance of the HS--600 High Speed Data System, contact your local Honeywell Dealer or regional Honeywell Customer Support Engineer. Additional assistance can be obtained from: • Honeywell...
  • Page 28: Figure 1-1. High Speed Data System Block Diagram

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 1 SYSTEM DESCRIPTION AND OPERATION 1. Overview A. General (1) The HS--600 high speed data system provides multi--channel Inmarsat Aero cockpit and passenger voice, fax, and data, and multi--media mini--M (M4) circuit--mode services simultaneously.
  • Page 29: Table 1-1. Sdu Dlt Rs--232 Port Configuration

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (2) The HSD system is capable of being integrated with the MCS--3000, MCS--6000, MCS--4000, and MCS--7000 multi--channel (MCS) satellite communications (SATCOM) systems with Aero--H/H+ high gain antennas (HGA). The HSD system is interfaced with its own dedicated 40 W high power amplifier (HPA).
  • Page 30: Table 1-3. Type Of Service

    (2) When used within the spot beams, Aero--H+ voice and data rates are lower. Therefore, it requires less power so that call charges are reduced. All Honeywell/Thales aeronautical equipment complies with the International Civil Aviation Organization (ICAO) Agency of the UN requirements for aeronautical safety services.
  • Page 31: Table 1-4. Assumptions

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System D. System Performance (1) Currently, the numbers of simultaneous aeronautical voice and M4 data channels can only be obtained from theoretical calculations. Using the assumptions given in Table 1-4, the calculations are given in Table 1-5. The calculations for the total number of calls are given in Table 1-6 thru Table 1-9.
  • Page 32: Table 1-7. Total Number Of Calls With Aero--H+ (Spot Beam Operation) And 600 Bps Packet Data Rate

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 1-7. Total Number of Calls with Aero- -H+ (Spot beam operation) and 600 bps Packet Data Rate M4 HSD Channels 8400 Voice Channels 21000 Voice Channels 5/6 (Note) NOTE: MCS 6000 = 5, MCS 7000 = 6 Table 1-8.
  • Page 33: Table 1-10. Components Supplied By Honeywell

    HS--600 High Speed Data System 2. System Components A. General (1) Table 1-10 gives the component part numbers supplied by Honeywell. Table 1-11 gives components that are necessary, but are not supplied by Honeywell. Table 1-10. Components Supplied by Honeywell Component Model No.
  • Page 34 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 3. Component Descriptions A. HS- -600 High Speed Data Unit (HSU) (1) The HSU is designed to perform reliably under field conditions and provide ease of maintenance when required. The HSU has a modular design to permit easy replacement of each circuit card assembly (CCA).
  • Page 35 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 1-2. HS- -600 HSU Page 1--8 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 36: Table 1-12. Hs--600 Leading Particulars

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 1-12. HS- -600 Leading Particulars Characteristic Specification Dimensions (maximum): • Length ....... . 7.64 in.
  • Page 37: Table 1-13. Do--160D Environmental Categories

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 1-13. DO- -160D Environmental Categories Description Category Temperature and Altitude In--Flight Loss of Cooling Temperature Variation Humidity Shock Vibration Explosion Proofness Waterproofness Fluids Susceptibility Sand and Dust Fungus Resistance Salt Spray Magnetic Effect Power Input...
  • Page 38: Table 1-14. Hsu Front Panel Light Description

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (4) Table 1-14 gives a description of the HSU front panel lights during various HSU conditions. The PUSH TO TEST switch on the front panel of the HSU is not operational.
  • Page 39: Figure 1-3. High Speed Combiner Assembly

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System B. High Speed Combiner Assembly (1) The high speed combiner assembly combines the signals from both HPAs which are then sent to the DLNA. Figure 1-3 shows the high speed combiner assembly. Figure 1-3.
  • Page 40: Figure 1-4. Rf Power Splitter

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System C. RF Power Splitter (1) The RF power splitter divides the signal from the DLNA which is then sent to the SDU and HSU. The unit weight is 2.5 oz. (70.87 grams). Figure 1-4 shows the RF power splitter.
  • Page 41: Table 1-15. Hsu Mounting Trays

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (2) Table 1-15 gives a list of HSU mounting trays available through ECS. Contact EMTEQ for a list of HSU mounting trays available. Table 1-15. HSU Mounting Trays ECS Part No. Description Voltage 6050--101...
  • Page 43 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 2 MECHANICAL INSTALLATION 1. Overview A. General (1) This section contains information on how and where to mount the HSU, combiner, and splitter. Figure 2-1 shows the HSU dimensions. Figure 2-2 shows the dimensions and mounting hole dimensions of the combiner.
  • Page 44 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page 2--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 45 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-1 (Sheet 1). HSU Outline and Installation Diagram 23- -20- -31 Page 2--3/2--4 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 46 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-1 (Sheet 2). HSU Outline and Installation Diagram 23- -20- -31 Page 2--5/2--6 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 47: Figure 2-2. High Speed Combiner Outline And Installation Diagram

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-2. High Speed Combiner Outline and Installation Diagram 23- -20- -31 Page 2--7/2--8 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 48: Figure 2-3. Rf Power Splitter Outline Diagram

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-3. RF Power Splitter Outline Diagram 23- -20- -31 Page 2--9 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 49: Figure 2-4. Typical Dimensions For 4--Mcu Tray Assemblies

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-4. Typical Dimensions for 4- -MCU Tray Assemblies Page 2--10 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 50: Figure 2-5. Typical Dimensions For 8--Mcu Tray Assemblies

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 2-5. Typical Dimensions for 8- -MCU Tray Assemblies 23- -20- -31 Page 2--11 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 51 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page 2--12 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 53 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 3 ELECTRICAL INSTALLATION 1. Overview A. General (1) This section gives electrical installation procedures, power distribution, and interconnect information for the HSU, combiner, and splitter. (2) Procedures for proper shield, power, and signal grounding are also provided in this section.
  • Page 54: Figure 3-1. Electric Cable Chart

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-1. Electric Cable Chart C. Ground Requirements (1) General (a) Proper grounding is a key factor in ensuring proper system operation under normal conditions, high intensity radiated electromagnetic frequencies (HIRF), and lightning environments.
  • Page 55: Figure 3-2. Example 1, Multi--Point Shield Ground

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (b) The mating surfaces must be free of all paint and other non--conductive elements and are burnished to ensure a good bond. If the aircraft mating surface is not conductive, a bonding strap of a least 1/4--inch wide (preferably 1/2--inch wide) tin coated copper braid can be used between the LRU mounting tray (or LRU itself if a tray is not used) and the nearest airframe grounding point.
  • Page 56: Figure 3-4. Shield Grounding Example For Rack Mount Connectors

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-4. Shield Grounding Example for Rack Mount Connectors (4) Power/Signal Grounds (a) All dc power grounds are tied together; all ac power grounds are tied together; all signal grounds are tied together; and all lighting grounds are tied together. DC power, ac power, signal and light ground groups are then tied together at a single point and connected to the airframe.
  • Page 57: Figure 3-5. Aircraft Grounding

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-5. Aircraft Grounding (b) Because signal grounds are low currents, multiple signal grounds can be connected to remote aircraft terminal blocks other than the central grounding blocks as long as these remote terminal blocks are isolated from ground. The various remote signal ground blocks must all be grounded only at the aircraft central grounding point.
  • Page 58: Figure 3-6. Hsu Arinc 600 Connector (P1) Pin Layout

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-6. HSU ARINC 600 Connector (P1) Pin Layout Page 3--6 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 59: Table 3-1. Contact Arrangements For P1--A Top Insert, Hsu Arinc 600 Connector

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 3-1. Contact Arrangements for P1- -A Top Insert, HSU ARINC 600 Connector RSVD RSVD RSVD RSVD RSVD RSVD ASYNC RSVD RSVD RSVD POTS APM IN APM WR POWER ENABLE ENABLE OUT CLK RING...
  • Page 60 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 3-2. Contact Arrangements for P1- -B Top Insert, HSU ARINC 600 Connector RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD RSVD CHASSIS SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE RSVD...
  • Page 61: Figure 3-7. Contact Arrangements For P1--C Bottom Insert, Hsu Arinc 600 Connector

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-7. Contact Arrangements for P1- -C Bottom Insert, HSU ARINC 600 Connector Figure 3-8. HSU Data Loader Connector (J1) Pin Layout 23- -20- -31 Page 3--9 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 62: Figure 3-9. Rf System Interface

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-9. RF System Interface Page 3--10 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 63: Figure 3-10. High Speed Data System Interconnect Diagram

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 3-10. High Speed Data System Interconnect Diagram 23- -20- -31 Page 3--11/3--12 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 65 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 4 INSTALLATION CHECK 1. Overview A. General (1) The procedures that follow are designed to check for the satisfactory installation of the HS--600 HSD system prior to LRU installation. 2.
  • Page 66: Table 4-1. Power Checks

    115 V ac (High) 115 V ac (Low) NOTE: The HPA is also available as 28V dc. See Honeywell Pub. No. C15--5111--005 for installation details. D. RF Checks (1) Check the pins listed in Table 4-2. Figure 4-1 shows the receive (RX) path loss and Figure 4-2 shows the transmit (TX) path loss.
  • Page 67: Figure 4-1. Rx Path Loss

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 4-1. RX Path Loss Figure 4-2. TX Path Loss 23- -20- -31 Page 4--3 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 68 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page 4--4 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 70: Table 5-1. Sdu To Pc Wire List

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 5 ADJUSTMENT/TEST 1. Overview A. General (1) This section provides instructions for adjusting/testing the HS--600 HSD system. 2. Details A. General (1) Access to the maintenance functions is obtained by connecting a personal computer (PC) to the RS--232 maintenance port connector.
  • Page 71: Figure 5-1. Sdu To Pc Cable

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Figure 5-1. SDU to PC Cable (3) Connect the PC using HyperTerminal, ProComm, or equivalent. (4) Set the terminal settings to: Direct Connect to Comm 1, 9600 N 81. (5) Press ENTER to see the SDU main menu. NOTE: Refer to paragraph 1.A.(5) in section 1 for the periodic data word setup.
  • Page 72: Typical Maintenance Port Start--Up Information

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (10) Set up the terminal according to paragraph 2.A.(2) of this section. (11) Once the SATCOM system is logged on, then the HS--600 system will log on. (12) View the maintenance port information for a typical start--up. Refer to paragraph 2.D. of this section.
  • Page 73 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 5-3. Typical HS- -600 Maintenance Port Information (cont) Glocom Multi Channel M4 Terminal IDU software start up... IDU SW Version: A1.00 04/05/2002 Initializing channel 0... copy bulletin board from flash memory ok, issue no is 23 Initializing channel 1...
  • Page 74 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 5-3. Typical HS- -600 Maintenance Port Information (cont) * Waiting for MSG_LOGON_ACK from ACSE. CHNL 0(T=14109) changed to OC--Reg 2 * Current state is LOG_ON. CHNL 0(T=14111) , got sync response from ODU,now request DSP setting... CHNL 0(T=14112) , got DSP settings , now load FPGA program...
  • Page 75: Maintenance Menu Items

    NOTE: Items listed in Table 5-4 are for reference only and will be set by the manufacturer. NOTE: Changes to the parameters listed in Table 5-4 should only be accomplished by qualified personnel or after consulting your Honeywell representative. Table 5-4. Maintenance Menu Items IIIIIIIIIIIIIIII Maintenance Parameters Setting IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII¯...
  • Page 76 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 5-4. Maintenance Menu Items (cont) Enter your selection: 4 ISE MUT--TO--HPA output gain range 36 to 42 dB, in 1 dB steps: 40Hz Please enter new value between 36 to 42: Keep current value! Enter your selection: 5 HPA output to antenna input loss,...
  • Page 77 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table 5-4. Maintenance Menu Items (cont) Enter your selection: S (NOTE: Must be Upper Case) Maintenance Parameters have been saved. The new maintenance parameters will be used by system. Please wait for system setup... NOTE: Must power cycle HS--600 for parameter save to take effect.
  • Page 79: Fault Isolation

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 6 FAULT ISOLATION 1. Overview A. General (1) To be supplied. 23- -20- -31 Page 6--1 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 80 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page 6--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 82: Maintenance Practices

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System SECTION 7 MAINTENANCE PRACTICES 1. Overview A. General (1) This section provides instructions for removing, reinstalling, and adjusting the HS--600 HSU, combiner, and/or splitter that has been previously installed by the aircraft manufacturer or completion center.
  • Page 83: Adjustment Procedures

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (2) Reinstall the HSU. (a) Remove the HSU from the protective carrying case and protective static--resistant bag. (b) Remove the electrostatic protective covers from the HSU rear connector. (c) Slide the unit into the mounting tray. CAUTION: WHEN PLACING THE UNIT ON THE MOUNTING TRAY, DO NOT FORCE FIT.
  • Page 84: Adjustment Procedures

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System (2) Reinstall the combiner. (a) Attach the combiner using six screws. (b) Remove the protective covers from the connectors and install the aircraft connectors on the combiner. (c) Reapply power to the HSU and its interfacing equipment. (3) Remove the splitter.
  • Page 85: Instructions For Continued Airworthiness, Code Of Federal Regulation

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 4. Instructions for Continued Airworthiness, Code of Federal Regulation CFR 91.213 A. General (1) Maintenance requirements and instructions for continued airworthiness of the HS--600 HSU components are contained in the following paragraphs: (2) Installation of the HSU on an aircraft by Supplemental Type Certificate or Form 337 obligates the aircraft operator to include the maintenance information provided by this manual in the operator’s Aircraft Maintenance Manual and the operator’s Aircraft...
  • Page 87: Appendix A M4 Call Cause Code List

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System APPENDIX A M4 CALL CAUSE CODE LIST 1. Overview A. General (1) The following list of cause codes in Table A--1 describes the various conditions of a failed M4 terminal call. Table A- -1.
  • Page 88 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 1012 MES is clearing the fixed--originated call because subsequent to the acceptance of the call and signaling of the identity of the mobile terminal to which the call will actually be routed, that terminal has become busy and therefore cannot be rung.
  • Page 89 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 11D2 Call Failed, Insufficient Digits in Service Address LES is clearing the call because the “Service Address” information received from the MES is invalid (e.g., less than 2 digits).
  • Page 90 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 12C1 Call Faded, No Scrambling Vector Ack MES clear: Scrambling Vector Ack (95) not received by the MES. 12C2 MES is clearing the call because a “Credit Card Valid”...
  • Page 91 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 1391 Aero Class MES only: MES is clearing the call because the call has lasted more than 700 km in linear travelled distance.
  • Page 92 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 15A3 LES is clearing the call because the “credit card data” information received from the MES has been rejected by the credit card authorization process. 15A4 LES is clearing the call because the data received from the MES in the “Authentication 1., 5.
  • Page 93 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 15CC Aeronautical Class MES only: (Spot Beam Handover): LES is terminating the procedure because it did not receive a response to the Handover Request from the NCS. 15CD (Spot Beam Handover): LES is clearing the call session in the next beam because the MES did not indicate that it was ready to make the transition (possibly because the MES did not...
  • Page 94 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 1853 NCS is rejecting the call because no SCPC channel is currently available for the specified leasemarked MES. Contact the NCS to verify that the MES has frequencies in a lease pool available or request that the MES ID be removed from the leasemark pool.
  • Page 95 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Table A- -1. Call Cause Code List (cont) Cause Code Description Note 1F21 Call Failed, LES Timeout, No Answer LES is clearing the call because appropriate “off--hook” signaling from the terrestrial called party has not been received by the LES within the allowed time limit.
  • Page 96 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Blank Page Page A--10 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 98: Inmarsat Registration Form

    SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System APPENDIX B INMARSAT REGISTRATION FORM 1. Overview A. General (1) This appendix provides an example of the Inmarsat registration form required to activate the HSD system. 23- -20- -31 Page B--1 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 99 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Page B--2 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 100 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 23- -20- -31 Page B--3 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 101 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Page B--4 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 102 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 23- -20- -31 Page B--5 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 103 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Page B--6 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 104 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 23- -20- -31 Page B--7 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 105 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Page B--8 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 106 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System 23- -20- -31 Page B--9 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
  • Page 107 SYSTEM DESCRIPTION AND INSTALLATION MANUAL HS--600 High Speed Data System Page B--10 23- -20- -31 30 May 2002 Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.

Table of Contents