All guidelines are based on a 3 in. (76mm) deep
sign for Tetra
EdgeStrip. When installing the
®
modules, it is typically recommended to install the
modules across the longest distance to allow for
the shortest light throw.
1 ft. (0.30 m)
1 ft.
EdgeStrip: 1 side
(0.30 m)
Modules/side: 1
2 ft.
EdgeStrip: 1 side
(0.61 m)
Modules/side: 2
3 ft.
EdgeStrip: 1 side
(0.91 m)
Modules/side: 3
4 ft.
EdgeStrip: 1 side
(1.22 m)
Modules/side: 4
5 ft.
EdgeStrip: 1 side
(1.52 m)
Modules/side: 5
6 ft.
EdgeStrip: 1 side
(1.83 m)
Modules/side: 6
7 ft.
EdgeStrip: 1 side
(2.13 m)
Modules/side: 7
Retrofit Instructions
1. (Existing Signs Only) Prior to installation, survey the site for information regarding power and accessibility inside and outside the
building. Ensure that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED
power supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
2. (Existing Signs Only) Remove the existing lighting equipment to be replaced, such as neon tubing or fluorescent tubes; and
associated transformers and ballasts. Care should be taken not to break the existing neon or fluorescent tubes.
NOTE: Follow all federal and local regulations when disposing of neon tubing, fluorescent tubes, transformers and ballasts.
3. (Existing Signs Only) If removal of the existing lighting equipment eliminates the disconnect switch, as required by applicable
local, state, or country electrical codes; a new disconnect switch must be installed.
4. (Existing Signs Only) Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in)
diameter require a metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed
with non-hardening caulk.
5. Using the layout guidelines above, determine required number of LED modules required to illuminate the sign.
6. A 24VDC Class 2 Power Supply, as listed below, must be used with this retrofit kit. Determine the number of Power Supplies required
to power the number of LED modules required to illuminate the sign, so as not to overload the Power Supply chosen.
7. Follow the instructions above to properly mount the LED modules.
8. Connect the DC output of the power supply to the LED modules using the Electrical Connections instructions above.
9. Connect the power unit to the supply in accordance with the applicable local, state, and country electrical codes, and the instructions
found in the power supply installation guide.
10. If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country
electrical codes.
2 ft. (0.61 m)
3 ft. (0.91 m)
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 2
Modules/side: 3
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 3
Modules/side: 5
EdgeStrip: 1 side
EdgeStrip: 2 sides
Modules/side: 5
Modules/side: 5
EdgeStrip: 1 side
EdgeStrip: 2 sides
Modules/side: 6
Modules/side: 6
EdgeStrip: 1 side
EdgeStrip: 2 sides
Modules/side: 8
Modules/side: 8
EdgeStrip: 1 side
EdgeStrip: 2 sides
Modules/side: 9
Modules/side: 9
EdgeStrip: 1 side
EdgeStrip: 2 sides
Modules/side: 11
Modules/side: 11
2 inches
Height
4 ft. (1.22 m)
5 ft. (1.52 m)
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 4
Modules/side: 5
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 6
Modules/side: 8
EdgeStrip: 2 sides
EdgeStrip: 2 sides
Modules/side: 6
Modules/side: 8
EdgeStrip: 4 sides
EdgeStrip: 4 sides
Modules/side: 6
Modules/side: 6-8
EdgeStrip: 4 sides
EdgeStrip:
Modules/side: 6-8
Not Recommended
EdgeStrip: 4 sides
EdgeStrip:
Modules/side: 6-9
Not Recommended
EdgeStrip: 4 sides
EdgeStrip:
Modules/side: 6-11
Not Recommended
4
Installation Guide
A 2 in. (51 mm) border is
recommended along the
perimeter of the sign.
6 ft. (1.83 m)
7 ft. (2.13 m)
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 6
Modules/side: 7
EdgeStrip: 1 side
EdgeStrip: 1 side
Modules/side: 9
Modules/side: 11
EdgeStrip: 2 sides
EdgeStrip: 2 sides
Modules/side: 9
Modules/side: 11
EdgeStrip: 4 sides
EdgeStrip: 4 sides
Modules/side: 6-9
Modules/side: 6-11
EdgeStrip:
EdgeStrip:
Not Recommended
Not Recommended
EdgeStrip:
EdgeStrip:
Not Recommended
Not Recommended
EdgeStrip:
EdgeStrip:
Not Recommended
Not Recommended

Advertisement

loading

This manual is also suitable for:

Gebi71-2Gebi50-2Gebi41-2Gebi32-2