Purpose; Scope; Reference; Glossary/Acronym List - Philips Fisio 120 VOICE Service Manual

Table of Contents

Advertisement

Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
1.0

PURPOSE

This document establishes the functional test and inspection procedures for the first level service repair of the
FISIO 120/121 transceivers.
2.0

SCOPE

The test plan is applicable to all levels of service repair of the FISIO 120/121 transceivers.
3.0

REFERENCE

None.
4.0

GLOSSARY/ACRONYM LIST

Board
LCD Module
SW
PN
CN
HW
ASC
NSC
Test SIM Card
Test SIM Card « SP »
5.0

TEST EQUIPMENT AND TOOLS

Equipment / Tools
- Test SIM Card « Production »
- Test SIM Card « SP »
- Data Connect Cable
- Fisio 120 Mat Software provided by Philips
- Digital Multimeter
Digital Radiocommunication Tester.
-
Coupling system with shielded chamber
-
-
RF Pliers With mechanical adaptation
Ó PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Transceiver Without LCD and Plastics parts
LCD part with plastic cover, earpiece and vibrator
Software
Hardware Configuration of the Mobile
Matrix for Types of SW used on the different hardware
Hardware
Authorized Service Center
National Service Center
Used for functionality of PHILIPS Mobile Phones
SIM Card used to simulate the user interface and enable radio tests
- Part No. : 4311 255 00781
- Part No. : 4311 255 00782
- Part No. : 4311 258 10392
- Recommended Model : Fluke
Specification with current reading in mA.
or
Service Repair Support
- Part No.: 4311 255 30041
COMPANY RESTRICTED
VY-V-640-120-2
Page : 4 of 45
Language : EN
Date : 23/04/02
VY-V-640-