Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.3.8
PCN Specification (1800 Mhz)
Test parameter
ÉMISSION
Phase error RMS
Phase error Peak
Frequency Error
Power Ramping
Modulation
Switching Transients
Timing Advance
Power reading
Output Power
RECEPTION
Rx Level
Rx Qual
Rx Level
Rx Qual
Rx Level
Rx Qual
TCH LOOP
SENSITIVITY
BER
FER
BER
FER
If a phone is out of the specifications, it must be sent to the Repair Center.
Ó PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
Channel
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
512, 700, 885
COMPANY RESTRICTED
Level
Standard specifications
0,5,10
0 to 5 degree
0,5,10
-20 to +20 degree
0,5,10
-180 Hz to + 180 Hz
0,5,10
0,5,10
0,5,10
0,5,10
Level 0
30 +/- 2 dBm
Level 10
10 +/- 4.0 dBm
Level 15
0 +/- 5.0 dBm
-102dbm
-102dbm
-85dbm
-85dbm
-60dbm
-60dbm
-85dbm
-85dbm
-102dbm
-102dbm
VY-V-640-
VY-V-640-120-2
Page : 26 of 45
Language : EN
Date : 23/04/02
Mask
Mask
Mask
+/- 1.00 bit
4 to 12
0 to 1
21 to 29
0
46 to 54
0
0%
0%
2.44%
0%