NEC Express5800/B120b User Manual page 37

Express5800/bladeserver series;
Table of Contents

Advertisement

On-screen message
Location Error
Cooling Error
Proc1 Therm % 07
Proc2 Therm % 07
CPUx_DIMMyTemp07 A high temperature warning was
AmbientTempAlm07
AmbientTempAlm00
P1 VCCP Alm XX
P1 VTT Alm XX
P1 VDDQ Alm XX
P1 DDR_VTT AlmXX
P2 VCCP Alm XX
P2 VTT Alm XX
P2 VDDQ Alm XX
P2 DDR_VTT AlmXX
BB +1.1v Alm XX
BB +1.5v Alm XX
BB +1.8v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +0.9vs Alm XX
BB +1.1vs Alm XX
BB +1.8vs Alm XX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Battery Alm XX
Description
In the Blade Enclosure, the
installation location of CPU blade
is incorrect, or the installation
locations of the fan and CPU
blade are incorrect. Thus, the
CPU blade failed to power on.
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty. Thus, the CPU blade failed
to power on due to insufficient
cooling power.
A high temperature warning was
detected in CPU #1.
A high temperature warning was
detected in CPU #2.
detected in DIMM.
x, y: Indicates location of DIMM
slot.
A high temperature warning was
detected in CPU blade.
A low temperature warning was
detected in CPU blade.
A voltage warning was detected
on CPU blade.
XX=07: Upper limit warning
XX=00: Lower limit warning
General Description 2-13
Action
Refer to the User's Guide of Blade
Enclosure to check if the CPU blade is
installed in correct location.
Check the installation locations of the fan
and CPU blade.
If the same error persists, contact your
service representative.
Check if the heat sink is installed
correctly on CPU blade.
Check if fans in Blade Enclosure work
normally.
Refer to the User's Guide of the Blade
Enclosure to make sure that the
sufficient number of fans are installed in
correct locations.
Check if the fans and CPU blades are
installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
If the same error persists, contact your
service representative.
Contact your service representative.