Advertisement

Quick Links

1.
Introduction ------------------------------------------------------------------------------- 2
2.
System Password and Master Card ----------------------------------------------------- 3
3.
Conception of Debug Mode --------------------------------------------------------------- 4
4.
Monitor Programming -------------------------------------------------------------------- 5
5.
Door Station Programming --------------------------------------------------------------- 8
5.2. How to modify parameters
5.4. Basic Configuration Detail
6.
Access Control by Unlock Code ---------------------------------------------------------- 13
7.
Proximity Card Access Security Programming ----------------------------------------- 15
8.
Debug Tools -------------------------------------------------------------------------------- 19
DPC-536 Programming and Debug Guide
CONTENTS
1

Advertisement

Table of Contents
loading

Summary of Contents for XtendLan DPC-536

  • Page 1: Table Of Contents

    DPC-536 Programming and Debug Guide CONTENTS Introduction ------------------------------------------------------------------------------- 2 System Password and Master Card ----------------------------------------------------- 3 Conception of Debug Mode --------------------------------------------------------------- 4 Monitor Programming -------------------------------------------------------------------- 5 4.1. What’s Room Code 4.2. How to acquire current Room Code 4.3. Program Monitor by means of Monitor’s keypad 4.4.
  • Page 2: Introduction

    1. INTRODUCTION This Manual includes two parts: programming and debug tools. 1.1 About Programming This part explains all the steps required to program Monitor Room Code and DPC Door Station in a standard system without any kind of restriction or different customization, by using the keypad and screen on the Door Station panel.
  • Page 3: System Password And Master Card

    SYSTEM PASSWORDS AND MASTER CARD 2.1. Administrator Code Administrator Code (Admin. Code for short in PROGRAM MENU) is used to configure the Door Stations in installations; it is also called Installer Code. With the Administrator Code, you can access all the program menus, fully configure the system, change all kinds of codes, parameters setting, using Debug Tools in Door Station etc.
  • Page 4: Conception Of Debug Mode

    3. Conception of DEBUG MODE 3.1. What’s Debug Mode Debug Mode is a special running state of Door Station, differs from Normal Mode, for the conveniences of system setting and diagnosing in installations. Debug Mode should only be launched by installers. When Door Station runs as Debug Mode, most system functions are operated just as it runs as Normal Mode, and available shortcuts and functions in Debug Mode are as below: Respond Monitor calling request, and automatically calls the Monitor back...
  • Page 5: Monitor Programming

    MONITOR PROGRAMMING 4.1. What’s Room Code Each Monitor in system must be programmed with an address (Room Code), i.e. the calling number. Room Code ranges from “0001” to “9999” and each Monitor Room Code must be unique in one building. Room Code is stored in each Monitor’s inner EEPROM memory, and does not lose even the monitor is power off.
  • Page 6: Program Monitor By Means Of Door Station

    4.4. Program Monitor by means of Door Station 4.4.1 Launch “Monitor Program” menu in Door Station You can enter programming state in both states: Normal or Debug mode. Please see as below: When in normal mode When Door Station is Input “8003”, then input Program Monitor Program is launched standby, press “#”...
  • Page 7 4.4.2 Monitor Programming Procedure Make sure before program: The Door Station is under Step 1: Monitor Program state. Press “CALL” button on the The Monitor is connected Monitor to be programmed correctly and is powered on. Step 2: Step 3: The previous Room Code is Input new Room code in showed, with hints in bottom line...
  • Page 8: Door Station Programming

    5. DOOR STATION PROGRAMMING 5.1. How to enter PROGRAM MENU During programming state, system functions are blocked temporarily. By keypad Make the Door Station get into Debug State, see Chapter 3.2 for reference. Under Debug Mode, press “#” twice to enter PROGRAM MENU.
  • Page 9: Program Menu Overview

    5.3. PROGRAM MENU Overview...
  • Page 10 5.4. Basic Programming Detail 5.4.1. PROGRAM > [1]Configuration Items Descriptions Factory set -1. Net Address As each Door Station must be programmed with a unique No address Netware address, so you must assign Net Address before the Door Station will works with Guard Unit. The valid Net Address is from 001 to 120, in 3-digits format.
  • Page 11 5.4.2. PROGRAM > [4] Information Items Descriptions Format -1. Hardware version To show the Door Station(including ACS) hardware information [MR-V5, ACS-V3] -2. Software version To show the Door Station(including ACS) software information [MR-V7, ACS-V2] -3. Manufacture Date To show the Door Station manufacturing date [YY-MM-DD] -4.
  • Page 12 5.4.4. PROGRAM > [9] Advanced Config Items Descriptions Default -1. Tone Select Select the chime of Door Station in calling wait state, 15 chord [11] tunes are available, key in 01 to 15 to select. Chord 11 -2. Image Memo Only valid if Image Memory is available.
  • Page 13: Access Control By Unlock Code

    6. Access Control by Unlock Code This part explains how to configure the access control by means of keypad, and management of Unlock Code. 6.1. How to use code unlock function There are two unlock mode: Common Unlock Mode, Private Unlock Mode, operation is shown as below. When the Door Station Common Mode: input Unlock Code directly;...
  • Page 14 6.2. How to enter Unlock Setting menu If Door Station runs as Debug State, you can press “#” twice to activate Program Menu, then select “2” to enter; However, if runs as Normal State, follow these steps to enter: > > [ 2 ] [ 1 ] [ 2 ] U n l o c k S e t t i n g - - - - - - - - - - - - - - - - - - - - - - - - - - - U n l o c k C o d e 1...
  • Page 15: Proximity Card Access Security Programming

    7. Proximity Card Access Security Programming This part explains how to configure the Proximity card access function, by means of keypad. Please note, to a Door Station without access security, all the related parameters can’t be updated. It is much convenient to manage access security and cards by means of IDS software in a networked system. The standard capacity is 500 cards, and can be upgraded to 5,000 cards if needed.
  • Page 16: Access Controller Programming

    7.2. Access Controller Programming Items Descriptions Factory setting -1. Access Security To activate or deactivate the Access Security Controller inside the According to Door Station, however, it is useless to a Door Station without Access security controller inside. If set to 1, activate; set to 0, Door Station deactivate.
  • Page 17: Card Management By Means Of Keypad

    7.3. Card management by means of keypad To authorize cards, enter Card Management first (refer Chapter 6.1 to), then select the item. Please note that the following operations are irreversible. 7.3.1. User Card Management Add User Card > > [ 7 ] [ 1 ] >...
  • Page 18: Master Card

    Card information Enter Card Information, and the screen will display the authorized User Cards count, and card read access events count. 7.3.2. Master Card Management Enter Master Card, and then read the card to be authorized as new Master Card. After this operation, the previous Master Card is deleted automatically.
  • Page 19: Debug Tools

    8. USING DEBUG TOOLS 8.1. How to enter debug tools menu > > D E B U G S T A T E < < > > D E B U G T O O L S < < - - - - - - - - - - - - - - - - - - - - - - - - - - - >...
  • Page 20 8.3. Debug Tools > Auto Dial Back The Auto-Dial-Back option is designed to simplify field debugging, and to realize single person testing. Also, it is always used to get a Monitor’s Room Code. After Auto-Dial-Back is activated, by pressing Monitor’s Call Button, the Monitor’s Room Code is shown at the Debug Message Area of screen.
  • Page 21 8.7. Debug Tools > Monitor Property command This command is designed to get the property of the Monitor. Follow the steps in next page: In Debug State, press “2”,”#” to Input Monitor’s Room Code in The properties of Monitor enter Debug Tools, select “6” 4-digits, and then press “#”...

Table of Contents