Download Print this page

Honeywell Οva-OmniLED R S Instruction Manual page 2

Led 24v centralized

Advertisement

Spot Installation:
1
Light direction
Escape Route (ER)
3
Step 1: In order to place the proper lens (Anti - panic or escape route), first be sure that the luminary is not
connected in the mains power supply and the battery is disconnected. A 5 lux lens (Part no.
2900XX.STR) is also available for order. Use the corresponding lens retaining cover depending on
the lens you will use.
Step 2: Put the lens on the retaining cover.
Step 3: Insert the cover with the lens on the luminary. Be carefull not to touch the LED with your hand.
To install the spot place the main unit on the false ceiling and follow the next steps.
Step 4: Bend one spring, to get into the holes of the suspended ceiling.
Step 5: Bend the other spring and push the luminaire upwards until it is securely mounted. The device is
now ready to operate.
Technical description
Part no.:
Operation Voltage:
Maximum Power Consumption:
Lumen output:
Produced in accordance with:
Ambient Temperature Range:
Relative Humidity:
Degress of cover protection:
Technical lifetime (light source):
Weight:
Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway
1
Anti-Panic Area (AP)
4
Οva-OmniLED R S LED 24V Centralized
15-30V DC, 17-27V AC, 50-60 Hz
EN 60598-1, EN 60598-2-22
2
5
138372
3.5W / 3.7VA
270 lm
o
-30 to 50 C
Up to 95%
IP20
> 100000 hours
145 gr
http://www.hls-nordic.com
GB

Advertisement

loading

This manual is also suitable for:

138372