Chapter 9 - Technical Data
Protection
Short-circuit overcurrent trip limit
Output current regulation limit
Overvoltage trip limit
Undervoltage trip limit
Overtemperature limit
Auxiliary voltage
Ground fault protection
Accessories
Keypad Control Panel
Control Panel Remote
Mounting Kit, NEMA 4 with
10 foot cable
Braking resistor
External braking chopper
RFI Filter
RS 232 adapter
Fieldbus adapters
82
3.5 x I
N
0.5 -1.5 x I
1.35 x U
240
0.65 x U
N
90 °C, heatsink
short-circuit protected
protects only the ACS 300 when an
ground fault occurs at motor output
ACS300CDP-PANEL
ACD200CBL
R0, R1, R2
R2
R0 Type S-492-10, (R1,R2 standard)
Release pending
Release pending
ACS 300 User's Manual
N
, 1.3 x U
480