Chapter 9 - Technical Data; Incoming Power; Output Power - ABB ACS 300 User Manual

Ac drives for speed control of 1/2 hp to 15 hp squirrel cage motors
Hide thumbs Also See for ACS 300:
Table of Contents

Advertisement

Incoming Power

Voltage
Frequency
Fundamental power factor

Output Power

Voltage
Frequency
Switching frequency f
Continuous load capacity,
constant torque at a maximum
ambient temperature of 50 °C
Overload capacity at a maximum
ambient temperature of
50 °C
Nominal motor voltage
Acceleration time
Deceleration time
1)
Check type-specific, refer to Table 1-1 and Table 1-2.
ACS 300 User's Manual

Chapter 9 - Technical Data

1 and 3 phase
208 to 240 V
1 and 3 phase
200 to 240 V
3 phase
380 to 480 V
48 to 63 Hz
approximately 0.98
3 phase, 0 to V
0 to 500 Hz
1.0 to 16.0 kHz
s
ACS 300 rated
current
Constant torque
Starting duty
200 to 240 V
360 to 500 V
0.1 to 1800 s
0.1 to 1800 s
±
10 %
-7%
+10%
±
10 %
AC LINE
see Figure 2-1
1.5 * I
1 min every 10 min,
N
if switching frequency < 8 kHz
1.5 * I
1 min every 10 min,
N
if switching frequency < 8 kHz
see Chapter 7 - Drive Parame-
ters
see Chapter 7 - Drive Parame-
ters
1)
1)
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents