(7) Follow safety precautions of the battery manufacture if batteries are used with
modules.
(8) Consult the manufacturer for proper installation on special vehicles such as boats and
campers.
(9) The modules must be mounted using clips on the long sides of the module according to our
installation manual .
(10) Remove the cable securing tapes and the cable holders carefully before installation.
(11) The connections must be completely done and locked
(12) When removing the connection, the lock part should be pressed.
(13) To extend the module connecting leads, the connecting method shall comply with
applicable law of each country.
(14) To extend the module connecting leads, only connectors from JAE Europe, Limited.
(KB1JS01PG2 / KB1JS01SG2L) can be used in accordance with IEC61646 Ed.2 and
IEC617730 Ed.1 as shown Fig. C.
Figure C: Connector type
<Positive electrode>
(15) Please keep the open-circuit condition in the PV modules before completing the
electrical wiring of PV system.
7.4 Operation
(1) When a part of the modules is shadowed, the hot spot may be caused. Therefore do not
shadow cells.
(2) The modules shall be maintained by qualified personnel.
(3) The electrical characteristics degrade when the front cover of the module becomes dirty.
(4) Do not pour solvent on the modules when cleaning.
(5) Do not produce sparks near flammable vapors.
(6) Do not expose the modules to sunlight concentrated with mirrors, lenses or similar
means.
(7) Keep modules away from children.
8. Others
Any doubt as to this specification shall be determined in good faith upon mutual consultation
of the both parties.
KB1JS01PG2
.
<Negative electrode>
MTA14004
KB1JS01SG2L