Download Print this page

Sharp NS-F128G6 Manual page 4

Advertisement

Filling materials shall be black resin.
4.2.4 Front cover
Front cover shall be low iron non-tempered glass.
4.2.5 Back cover
Back cover shall be tempered glass.
<NOTE>
Tempered glass used as the back cover material might cause a spontaneous breakage because of
the impurity in the tempered glass.
4.2.6 Terminal box
The termination shall be lead wire system. The main material of the terminal box shall be
PPE/PPO resin.
4.2.7 Bypass diode
One bypass diode shall be installed in the terminal box.
4.3 Mechanical design
4.3.1 General
The design of module is suitable for long-term operation in general open-air climates.
4.3.2 Interconnection of solar cells
In-series connection between the unit solar cells in a-module is formed by the laser
patterning process at the time of manufacture.
4.3.3 Termination
The termination shall be lead wire type with 2.5mm
Connector is JAE Europe, Ltd. connector. (Model KB1JS01PG2, KB1JS01SG2L).
4.3.4 Mass
The typical mass of modules is shown in the appended data sheet.
4.3.5 Dimension
The typical size of modules: 1402mm×1001mm×24mm
The tolerance in dimension of module is shown in Fig.1 and Fig. 2.
4.4 Identification and product marking
The nameplate design as the identification and product marking is shown in Fig. 3.
4.5 Appearance
The followings shall be considered to be major visual defects:
1) Broken, cracked or torn external surface, including front cover, back cover and terminal
box;
2) Bent or misaligned external surfaces, including front cover, back cover and terminal box to
extent that the installation and/or operation of the module would be impaired.
3) Voids in, or visible corrosion, or visible de-lamination of any of the thin-film layers of the
active circuitry of the module, extending over more than 10% of the module.
4) Bubbles or delaminations forming a continuous path between any part of the electrical
circuit and the edge of the module.
5) Loss of mechanical integrity, to the extent that the installation and/or operation of the
module would be impaired.
/14AWG.
2
MTA14004

Advertisement