Chapter 4. Error Codes and Troubleshooting
4.1 User Restrictions
If a Dangerous Detected state occurs, the flowmeter will put the SIL Output in the DD state and remain that way until
an Authorized User intervenes. The DD state can be cleared by executing a reset of the flowmeter. There are two
methods for clearing the DD state:
1. Enter the Program menu at SIL user access level. Then exit without making any changes. The flowmeter will
execute a soft reset.
2. Turn off power, wait 1 minute, turn power back on.
4.2 Error Display in the User Interface
The bottom line of the LCD displays a single, top priority error message during Measurement Mode. This line, called
the Error Line, includes two parts: Error header and Error String. The Error header indicates the error pattern and error
number, while the Error string gives a detailed description of the error information
4.2.1 Error Header
PanaFlow HT User's Manual
Table 3: Error Header
Error Pattern
Communication error
Flow error
SIL error
XMIT error
OPT error
Error Header
Cn(n is error number)
En(n is error number)
Sn(n is error number)
Xn(n is error number)
On(n is error number)
Chapter 4. Error Codes and Troubleshooting
75