Configuring The Com Port - Panasonic MICRO-IMAGECHECKER PV310 Use Manual

Hide thumbs Also See for MICRO-IMAGECHECKER PV310:
Table of Contents

Advertisement

11.3.5 Configuring the COM Port

Be sure to specify the same parameters for COM port as that for the COM port setting for the communication
destination PLC.
Item
Selections
Baud rate
1200 to 115200 (Initial Value: 9600)
(bps)
Bit length
7 or 8 (Initial Value: 8)
Stop Bit
1 or 2 (Initial Value: 1)
Parity
None/Odd/Even (Initial value: Odd)
Flow Control
None/Soft Flow (Initial value:
None)
Setting Procedure
1.
In SETUP mode, select "ENVIRONMENT" > "Serial Communication" from the menu bar.
2.
Open the RS232C tab.
When PLC Model is set to "MELSEC FX" or "MICREX SX", the setting values for the port are fixed.
When you use MELSEC FX series, store "0" in the MELSEC FX register for specifying communication
format.
Register for specifying communication format: D8120 (or D842020)
Description
Transmission speed for communication. The higher
number the faster communication speed.
To set the bit number per word.
To set the bit number of the signal that recognizes the
end of data.
To specify the number of overhead bits to check for
proper data transmission.
To set how to control the handshake flow.