Mounting and Connection Instructions IDENTLOC Evaluation Unit
7.4.2

Operation at BUS-1

- Set DIP switch
S2/2
in position
- Select address mode:
Set the desired address mode using DIP switch S1/7:
S1/7 ON
1-Address mode: All 5 sensors have a
S1/7 OFF 5-Address mode: Every sensor has its
Please note!
In order to prevent double allocation of addresses when switching from 1 to 5
address mode- or unintentional sensor zone allocations when switching from 5 to 1
address mode, this setting iy only possible when the EU is de-energized.
If the address mode is altered, the
type allocated. (see corresponding instructions on the

7.4.3 BUS user address

The DIP switches S1/1 to S1/6 are used for coding the BUS-2 or BUS-1 user address. The illustration above shows the position
and valence of the switches.
In the event of several users, each user must receive its own address.
When using BUS-1 in 5 address mode (see 7.3), ensure that the 4 automatically allocated addresses are not already occupied by
other users.
7.5

LED indication

In the operating state "disarmed cleared":
After disarming in case of a previous alarm:
A glass breakage message always remains stored at every operating state until it is cleared.
Totalling indicator:
- If triggered:
- In the event of glass breakage:
LED lights up
3Hz
Housing closed:
Totalling
Function
LED
At least 1 sensor has triggered
In indication mode: Cover contact has triggered
3Hz
At least 1 IDENTLOC sensor has signaled glass breakage
Housing open:
Note: A
tamper message
contact.
Totalling
Sensor-
Sensor-
LED
LED 1-4
LED 5
3Hz
3Hz
OFF
common
own
BUS-1
users must be re-entered in the programming of the
- LED indication of current state of sensors and total indication.
- The indication remains stored until it is cleared.
The totalling indication is OR-linked with the 5 sensor LEDs.
The glass breakage totalling indicator has priority over the trigger indicator. As soon as a
sensor indicates glass breakage, the LED totalling indicator flashes even if triggering is
simultaneously impending.
LED flashes, indicating flashing frequency
is transmitted to the control panel through the open cover
Function
Allocated sensor has triggered
End of line resistor outside tolerance/detector has triggered
Allocated sensor has signaled glass breakage
address.
address.
control panel
).
LED does not apply in this case
S2
BUS-2
BUS-1
No function
Teach. mode
Normal mode
1-add. mod.
5-add. mod.
32
16
8
BUS-2/1
address
4
2
1
S1
ON
control panel
and the user
LED
totalling
LED
indicator
Sensor 1
LED
Teaching mode
LED
Sensor 2
S2
LED
Sensor 3
S1
LED
Sensor 4
LED
Sensor 5
25