Honeywell SmartLine RM60 Handbook
Honeywell SmartLine RM60 Handbook

Honeywell SmartLine RM60 Handbook

24 ghz non-contact radar (fmcw) level meter
Table of Contents

Advertisement

Quick Links

SMARTLINE
SMARTLINE
SMARTLINE
SMARTLINE
24 GHz Non-contact Radar (FMCW) Level Meter
for distance, level, voume and mass measurement of solids
®
RM60 (FMCW)
RM60 (FMCW)
RM60 (FMCW)
RM60 (FMCW)
Handbook
Handbook
Handbook
Handbook

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell SmartLine RM60

  • Page 1 ® SMARTLINE SMARTLINE SMARTLINE SMARTLINE RM60 (FMCW) RM60 (FMCW) RM60 (FMCW) RM60 (FMCW) Handbook Handbook Handbook Handbook 24 GHz Non-contact Radar (FMCW) Level Meter for distance, level, voume and mass measurement of solids...
  • Page 2 Copyright 2015 by Honeywell WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective.
  • Page 3 Operation, and Troubleshooting of your device. Contacts Contacts Contacts Contacts World Wide Web: The following lists Honeywell’s World Wide Web sites that will be of interest to our customers. Honeywell Organization Honeywell Organization WWW Address (URL) WWW Address (URL) Honeywell Organization...
  • Page 4 ABOUT THIS DOCUMENT SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 5: Table Of Contents

    3.7.6 How to open the weather protection ..................33 4 Electrical connections 4.1 Safety instructions......................35 4.2 Electrical installation: outputs 1 and 2 ................35 4.2.1 Non-Ex devices ........................36 4.2.2 Devices for hazardous locations................... 36 4.3 Protection category ......................37 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 6 7.4 How to replace device components ................77 7.4.1 Service warranty ........................77 7.4.2 Replacement of the display cover..................78 7.4.3 Replacement of the complete electronic module ..............80 7.4.4 Replacement of the terminal module................... 82 www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 7 9.9.1 Overview AMS menu tree (positions in menu tree) ............111 9.9.2 AMS menu tree (details for settings).................. 111 10 Appendix 10.1 Order code ........................115 10.2 List of spare parts ...................... 119 10.3 List of accessories...................... 121 10.4 Glossary ........................123 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 8 CONTENTS SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 9: Safety Instructions

    10. • Low-Voltage Directive 2006/95/EC in conjunction with EN 61010-1 (2001). All devices are based on the CE marking and meet the requirements of NAMUR Guideline NE 21 and NE 43. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 10: Electromagnetic Compatibility

    1 CE sign 2 Notified body number (0682 = CETECOM) 3 Class II identifier According to ETSI EN 302 372-2 (2011), the radiated power outside a metallic silo is less than -30 dBm. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 11 18°33'30" E Russia Dmitrov 56°26'00" N 37°27'00" E Kalyazin 57°13'22" N 37°54'01" E Pushchino 54°49'00" N 37°40'00" E Zelenchukskaya 43°49'53" N 41°35'32" E Spain Yebes 40°31'27" N 03°05'22" W Robledo 40°25'38" N 04°14'57" W 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 12: And Canada

    FCC and IC authorizations to operate this equipment. This legal information is shown on a label on the rear side of the device. The radio approval report is given on the DVD-ROM supplied with the device. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 13: Safety Instructions From The Manufacturer

    The manufacturer reserves the right to alter the content of its documents, including this disclaimer in any way, at any time, for any reason, without prior notification, and will not be liable in any way for possible consequences of such changes. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 14: Product Liability And Warranty

    This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. Special considerations and precautions are also described in the document, which appear in the form of icons as shown below. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 15: Warnings And Symbols Used

    In general, devices from the manufacturer may only be installed, commissioned, operated and maintained by properly trained and authorized personnel. This document is provided to help you establish operating conditions, which will permit safe and efficient use of this device. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 16 SAFETY INSTRUCTIONS SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 17: Device Description

    1 Signal converter and antenna in compact version 2 Antenna extensions (option) and O-ring for each antenna extension 3 Quick Start 4 CD-ROM (including Handbook, Quick Start, Technical Datasheet, and related software) INFORMATION! No special tools or training required! 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 18: Device Description

    • Stainless steel weather protection. ® • RS232 / HART converter (VIATOR). ® • USB / HART converter. • 2° PP slanted flange INFORMATION! For more data on accessories, refer to List of accessories on page 121 www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 19: Visual Check

    Look at the device nameplate to ensure that the device is delivered according to your order. Check for the correct supply voltage printed on the nameplate. INFORMATION! Compare the material references on the side of the process connection with the order. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 20: Nameplates

    4 Degree of ingress protection (according to EN 60529 / IEC 60529) 5 Customer tag number 6 Date of manufacture 7 Order number 8 Type code (defined in order) 9 Model name and number 10 Company name and address www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 21: Installation

    3 Storage temperature range: -40...+85°C / -40...+185°F • Store the device in a dry and dust-free location. • Keep the converter out of the sunlight. • Store the device in its original packing. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 22: Transport

    • Protect the signal converter from direct sunlight. If necessary, install the weather protection accessory. • Do not subject the signal converter to heavy vibrations. The devices are tested for vibration and agree with EN 50178 and IEC 60068-2-6. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 23: How To Prepare The Silo Before You Install The Device

    The operating pressure range is subject to the process connection used and the flange temperature. Antenna type Maximum process connection Maximum operating pressure temperature [°C] [°F] [barg] [psig] PP Drop +100 +210 PTFE Drop +150 +300 Horn / Sheet metal horn +200 +390 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 24: Recommended Mounting Position

    Do not put the device near to the product inlet. If the product that enters the silo touches the antenna, the device will measure incorrectly. If the product fills the silo directly below the antenna, the device will also measure incorrectly. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 25: Installation Recommendations For Solids

    If it is not possible to install the device on another part of the silo, do an empty spectrum scan. INFORMATION! We recommend that you configure the device when the silo is empty. INFORMATION! For the best device performance, the antenna should be silo-intrusive. Refer to the illustration that follows. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 26: How To Install The Device On The Silo

    3.7.1 How to install a device with a flange connection Equipment needed: • Device • Gasket (not supplied) • Nuts and bolts (not supplied) • Wrench (not supplied) Requirements for flange connections Figure 3-8: Flange connection www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 27 • Lift the device a small distance. Attach the antenna locking screw to the part below the flange. Tighten the antenna locking screw. • Put the device carefully on the silo flange. Tighten the flange bolts. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 28: How To Install A Device With A Threaded Connection

    • Tighten the connection. Refer to local rules and regulations for the correct torque to apply to the connection. Figure 3-11: How to attach the device if the antenna is larger than the process connection www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 29: How To Attach Antenna Extensions

    • Tighten the connection. 3.7.3 How to attach antenna extensions Horn antenna - antenna extensions Figure 3-12: Horn antenna - how to attach antenna extensions Equipment needed: • 3 mm Allen wrench (not supplied) 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 30 Supervisor mode. Go to Supervisor > Advanced setup > Installation > Supervisor > Advanced setup > Installation > Supervisor Supervisor Supervisor > Advanced setup > Installation > Supervisor > Advanced setup > Installation > Antenna Extension. Antenna Extension Antenna Extension Antenna Extension www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 31: How To Turn Or Remove The Signal Converter

    If you remove the converter, put a cover on the wave guide hole on top of the process connection assembly. When the converter is attached to the process connection assembly, tighten the lock screw. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 32: How To Attach The Weather Protection To The Device

    • Turn the weather protection so that the keyhole points forward. • Attach the bracket. • Lift the weather protection to the top of the housing support pillar. • Hold the weather protection in the correct position and tighten the bracket nuts. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 33: How To Open The Weather Protection

    • Put a large slotted tip screwdriver into the keyhole at the front of the weather protection. Turn the screwdriver counterclockwise. • Pull the top of weather protection up and forward. This will open the weather protection. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 34 INSTALLATION SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 35: Electrical Connections

    7 Grounding terminal between the process connection and the converter ® Output 1 energizes the device and is used for HART communication. If the device has the second current output option, use a separate power supply to energize output 2. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 36: Non-Ex Devices

    (ATEX, IECEx, FM, CSA etc.). You can find this documentation on the DVD-ROM delivered with the device or it can be downloaded free of charge from the website (Download Center). www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 37: Protection Category

    • The cables are in a loop in front of the device 1 so water does not go into the housing. • Tighten the cable feedthroughs 2. • Close unused cable feedthroughs with dummy plugs 3. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 38: Networks

    Figure 4-4: Point-to-point connection (non-Ex) 1 Address of the device (0 for point-to-point connection) 2 4...20 mA + HART® 3 Resistor for HART® communication 4 Power supply 5 HART® converter 6 HART® communication software www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 39: Multi-Drop Networks

    1 Address of the device (n+1 for multidrop networks) 2 Address of the device (1 for multidrop networks) 3 4 mA + HART® 4 Resistor for HART® communication 5 Power supply 6 HART® converter 7 HART® communication software 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 40 ELECTRICAL CONNECTIONS SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 41: Start-Up

    It is also supplied on the DVD-ROM delivered with the device. ® • A connection to a HART Field Communicator. You can download the Device Description (DD) file from the website. It is also supplied on the DVD-ROM delivered with the device. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 42: Digital Display Screen

    Enter [^ ^ ^ ^ ] Down [ ] Up [ ] Esc (Escape) [> > > > ] + [ ] Operator mode For data on keypad functions, refer to on page 45. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 43: Help Screens

    The software and installation instructions are given on the DVD-ROM supplied with the device. You can also download the latest version of PACTware™ and the DTM from our internet site. Refer also to the PACTware™ consortium site at http://www.pactware.com. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 44: Remote Communication With The Ams™ Device Manager

    • Help plan preventive maintenance to reduce a plant's downtime to a minimum. The DD file is given on the DVD-ROM supplied with the device. You can also download it from our website. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 45: Operation

    3 Push this button after the selection of the signal screen. For more data, refer to "Operation: How to make the device follow the correct level or interface signal". 4 Level, distance, volume etc. 5 Push this button for 3 seconds. Push the button again and it will go back to the original language. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 46 3 This screen shows a graph of discrete radar reflection signals against distance. This graph is used to monitor reflec- tions measured by the device. Push [>] to move the cursor from one signal peak to another. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 47: Supervisor Mode

    You cannot select "Service menu" in supervisor mode. Menus that can be selected are in black text. Menus that cannot be selected are in gray text. If you go back to operator mode, you will have access to the supervisor mode, without password security, for 30 minutes. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 48: Menu Overview

    Quick Link 3 (default: Language) Quick Link 4 (default: Length Unit) Quick Link 5 (default: Display Mode) B Test Test Information C Advanced Setup Installation Setup Output 1 (HART) Output 2 (Passive) Device Setup Reset 1 Optional www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 49: Keypad Functions

    Go to the next menu level — Enter Down Move the menu selection bar down the list Move the menu selection bar up the list Esc (Escape) Go back to the menu level you were on before 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 50 Move the menu selection bar down the list Move the menu selection bar up the list Esc (Escape) Go back to the menu 1 This does not confirm that you selected a new parameter www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 51 Select the parameter and go back to the menu Down Decrease the digit value Increase the digit value Esc (Escape) Go back to the menu 1 This does not confirm that you selected a new parameter 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 52 • The device will ask you to save or cancel your settings. Select Save Save to accept the new settings Save Save or Cancel Cancel Cancel to reject them. Cancel The display goes back to operator mode. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 53: Function Description

    Is your tank If the silo is partially filled, the Partially Filled, Empty Partially partially filled or device must include the silo Filled empty? contents when it filters the signal. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 54 Table Length Unit m, cm, mm, inch, ft, Free Unit Please select Select "Mass". Mass Volume / Mass Do you want to use Yes, No the density of the product? Product Density min-max: 0…20000 kg/m3 www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 55 4 mA (output 1). 0…20 m / 0…65.62 ft Output 1 (HART): This assigns a measurement min-max: Depends on <Function> 20 mA value to 20 mA (output 1). 0…90 m / 0…295.29 ft the output function 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 56 Go to a function in the Measure- Advanced Setup menu Advanced Setup menu and ment push [> > > > ] for 1 second. You Quality can store up to 5 functions in this way. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 57 HART® parameters. B.2.2 15 Min Log A log of output values for the last 15 Read only minutes. A log is taken every 10 seconds and displayed on a graph. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 58 "Flat surface". If there is a slightly uneven surface, select "Medium slope". If the surface has a steep slope, select "Steep slope". C.1.4 Stillwell Height Not available. For liquid applications only. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 59 The interference signal must not be near to the level signal. C.1.14 Product Er Not available. For liquid applications only. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 60 Give a measurement value to 20 mA. min.-max: Depends on the output function C.3.4 Output Range Sets the effective range of output 1 min.-max: 3.8…20.5 mA 4…20 mA either with or without over-run. (NAMUR), 4…20 mA www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 61 (level 1) and black 7, Level 8, Level 9 (level 9). C.5.1.4 Length Unit The length unit displayed in operator m, cm, mm, inch, ft, mode. ft-inch-1/16inch, ft-inch-1/32inch, Free Unit 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 62 <20 mA Setting for Mass 0 kg Distance <20 mA Setting for Distance Ullage Volume 0.00 m³ <20 mA Setting for Ullage Volume 0 m³ Ullage Mass 0.00 kg <20 mA Setting for Ullage Mass 0 kg www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 63: Further Information On Device Configuration

    The device uses HART® communication to send information to HART®-compatible equipment. It can operate in either point-to-point or multidrop mode. The device will communicate in multidrop mode if you change the HART® address of output 1. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 64: Linearisation

    The device will go back to operator mode. 6.4.4 Distance measurement The device displays distance measurements when an output is set to distance. Menu items related to distance measurement are: • Output Function (C.3.1 or C.4.1) • Tank Height (C.1.2) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 65: Level Measurement

    Function description For more data about the menu items, refer to on page 53, table C. Advanced setup. 6.4.5 Level measurement The device displays level measurements when an output is set to level. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 66 5 20 mA Setting (C.3.3 or C.4.3) 6 4 mA Setting (C.3.2 or C.4.2) 7 Non-measurement zone Function description For more data about the menu items, refer to on page 53, table C. Advanced setup. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 67: How To Configure The Device To Measure Volume Or Mass

    Sudden changes in the cross section. • This will make volume measurement more accurate. Figure 6-6: A plot of points for a volume or mass table 1 Silo with reference points 2 Silo model with plotted points 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 68: How To Make A Filter To Remove Radar Signal Interference

    • Push [^ ^ ^ ^ ]. Do you want to save the spectrum. Select Yes Yes or No No and then push [^ ^ ^ ^ ]. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 69: How To Measure Correctly In Silos With Curved Or Conical Bottoms

    • Push [> > > > ] and [ ] (Esc) at the same time to exit to the "save settings" window. • Select Save Save and push [^ ^ ^ ^ ]. Save Save The device will go back to operator mode. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 70: Service Mode

    Please contact your local sales office for further information. 6.6 Errors 6.6.1 General information Indication of errors When the device senses an error condition, it displays an error symbol in the top left corner of the display screen. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 71 • For solutions to the problem, refer to Error handling on page 73. Figure 6-10: Measurement quality in supervisor mode 1 Type of error. 2 Error "active" 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 72 • For solutions to the problem, refer to on page 73. Figure 6-12: Description of the error 1 Description of the error 2 Time since error occurred in Days:Hours:Minutes:Seconds 3 Type of error www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 73: Error Handling

    -40...+175°F. If the device does not operate correctly, contact the supplier. One of the electronic boards Replace the electronics is defective. block. For more data, refer to Replacement of the complete electronic module on page 80. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 74 Hardware peripheral devices If the problem continues, on the DSP board failed. contact the supplier or replace the electronics block. For more data, refer to Replacement of the complete electronic module on page 80. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 75 Restart the device. If the download correctly to the problem continues, contact DSP board. the supplier or replace the electronics block. For more Replacement of data, refer to the complete electronic module on page 80. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 76 OPERATION SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 77: Service

    6 bar / 87 psi. 7.4 How to replace device components 7.4.1 Service warranty Maintenance is not necessary for most applications. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 78: Replacement Of The Display Cover

    This housing can be detached from the flange system under process conditions. Use only authorized service staff to repair the device. 7.4.2 Replacement of the display cover Figure 7-1: Removal of the device display cover www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 79 Make sure the connector is correctly turned. Do not use force to connect the ribbon cable. • Close the display. Tighten the screw on the display. • Attach the sun cover. Attach the 2 small screws that keep the sun cover attached to the housing. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 80: Replacement Of The Complete Electronic Module

    SERVICE SMARTLINE® RM60 (FMCW) 7.4.3 Replacement of the complete electronic module Figure 7-2: Removal of the complete electronic module www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 81 • Connect the display ribbon cable to the back end electronics block. • Connect power supply connector to the back end electronics block. • Close the display. Tighten the screw on the display. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 82: Replacement Of The Terminal Module

    SERVICE SMARTLINE® RM60 (FMCW) 7.4.4 Replacement of the terminal module Figure 7-3: Removal of the terminal module www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 83 • Attach the plastic terminal cover. • Connect the 2 wires from the power supply. Make sure that the polarity of the wires is correct. • Attach the terminal compartment cover. • Tighten the cover stop screw. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 84: Spare Parts Availability

    • such dangerous substances, to enclose a certificate with the device confirming that is safe to handle and stating the • product used. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 85: Form (For Copying) To Accompany A Returned Device

    The user must dispose of the WEEE to a designated collection point for the recycling of WEEE or send them back to our local organisation or authorised representative. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 86 SERVICE SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 87: Technical Data

    3 Antenna 4 Distance to product surface, where change in frequency is proportional to distance 5 Differential time delay, Δt 6 Differential frequency, Δf 7 Frequency transmitted 8 Frequency received 9 Frequency 10 Time 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 88: Technical Data

    Display and user interface Display and user interface Display LCD display 9 lines, 160 × 160 pixels in 8-step grayscale with 4-button keypad Interface languages English, German, French, Italian, Spanish, Portuguese, Japanese, Simplified Chinese and Russian www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 89 IEC 60068-2-6 and EN 50178 (10...57 Hz: 0.075 mm / 57...150 Hz:1g) Protection category IP66/67 equivalent to NEMA type 4X (housing) and type 6P (antenna) Maximum rate of change 10 m/min / 33 ft/min 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 90 DN80 in PN40 (Type B1), DN100…200 in PN16 or PN40 (Type B1); others on request ASME B16.5 3¨…8¨ in 150 lb RF, 3¨...4¨ in 300 lb RF; others on request JIS B2220 80…100A in 10K; others on request Other Others on request www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 91 Cl. I / Zone 0 / AEx ia / IIC / T6-T1; Cl. I / Zone 2 / AEx nA[ia] / IIC / T6-T1 Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 92 2 Kalrez® is a registered trademark of DuPont Performance Elastomers L.L.C. 3 Metaglas® is a registered trademark of Herberts Industrieglas, GMBH & Co., KG 4 HART® is a registered trademark of the HART Communication Foundation www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 93: Antenna Selection

    5 DN150 horn, DN200 horn and DN150 Drop antenna 6 DN100 horn, DN150 horn, DN150 Drop and DN200 horn antenna 7 DN80 horn, DN80 Drop, DN100 horn, DN150 horn, DN150 Drop and DN200 horn antenna 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 94: Guidelines For Maximum Operating Pressure

    Figure 8-5: Pressure / temperature de-rating (EN 1092-1), flange and threaded connections, in °F and psig 1 p [barg] 2 T [°C] 3 p [psig] 4 T [°F] 5 Threaded connection, G (ISO 228-1) 6 Flange connection, PN40 7 Flange connection, PN16 www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 95 Figure 8-7: Pressure / temperature de-rating (ASME B16.5), flange and threaded connections, in °F and psig 1 p [barg] 2 T [°C] 3 p [psig] 4 T [°F] 5 Threaded connection, NPT (ASME B1.20.1). 6 Flange connection, Class 300 7 Flange connection, Class 150 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 96: Dimensions And Weights

    12 mm or 0.28 … 0.47 ¨ • Cable glands for FM- or CSA-approved devices must be supplied by the customer. • A weather protection cover is available on request with all devices. • www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 97 2 Weather protection, left side view Dimensions and weights in mm and kg Dimensions [mm] Weights [kg] Weather 231.5 protection 1 Radius Dimensions and weights in inches and lb Dimensions [inches] Weights [lb] Weather 10.6 protection 1 Radius 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 98 Flange 10.4 18.9 24.4...41.5 connection 1 If fitted with standard cable glands 2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available 3 With distance piece option: add 2.8¨ to this dimension www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 99 10.4 21.6 11.3 25.6...62.2 connection 1 If fitted with standard cable glands 2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available 3 With distance piece option: add 2.8¨ to this dimension 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 100 1 Sheet metal horn antenna (DN80/3¨, DN100/4¨, DN150/6¨ or DN200/8¨) with G 1½ or 1½ NPT thread connection 2 Sheet metal horn antenna (DN80/3¨, DN100/4¨, DN150/6¨ or DN200/8¨) with flange connection 3 Antenna purging system (supplied with ¼ NPTF connection) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 101 DN200/8¨ 10.3 34.6 24.3 32.9 1 If fitted with standard cable glands 2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available 3 With distance piece option: add 2.8¨ to this dimension 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 102 Flange connection with flange 15.1 — 13.9…59.1 plate protection option 1 If fitted with standard cable glands 2 Additional antenna extensions of Ø1.5 × length 4.1¨ available. Do not attach more than 5 antenna extensions. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 103 Flange connection with flange 18.1 62.2 plate protection option 1 If fitted with standard cable glands 2 Additional antenna extensions of Ø1.5 × length 4.1¨ are available. Do not attach more than 5 antenna extensions. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 104 TECHNICAL DATA SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 105: Description Of Hart Interface

    9.2 Software history INFORMATION! In the table below, "x" is a placeholder for possible multi-digit alphanumeric combinations, depending on the available version. Release date Devices HART® Device Revision DD Revision 2010-11 All revisions 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 106: Connection Variants

    Up to 15 devices may be installed in parallel (this signal converter and other HART® devices). Multi-drop networks For an illustration of multi-drop networks, refer to on page 39. Network configuration For data on communication in multi-drop mode, refer to on page 63. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 107: Hart® Device Variables

    Protection of settings is the same as on the device's local display. The Field Communicator always saves a complete configuration for communication with AMS. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 108: Asset Management Solutions (Ams)

    Device DTM on the DVD-ROM or in the "Downloads" section of the website. 9.7.2 Operation The DTM and the device's local display use almost the same procedures to operate the signal converter. For more data, refer to Operation on page 45. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 109: Hart ® Menu Tree For Basic-Dd

    / 3 %Level Rd, Opt 2 HART variables 1 Manufacturer 2 Model 3 Field Software Version 1 Main CPU Version / 2 Comp. CPU Version / 3 DSP Version 4 Dev id 5 Polling Address 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 110 Handling / 9 Polling Address 4 Output2 1 Distance 4 mA / 2 Distance 20 mA / 3 Output Range / 4 Error Handling 5 Reset 1 Customer Reset / 2 Device Restart www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 111: Menu Tree For Ams

    Length Unit / Volume Unit / Mass Unit / Table Length Unit / Conversion Unit / Custom. Length Unit / Custom. Length R... / Custom. Conv. Unit / Product Density / Output2 Status / Conversion Flag 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 112 / Field device malfunction Critical (Errors) Spectrum Quality Bad / Spectrum Invalid / No Peak Plausible Temperature Out Of Range / Self Test Failed / Microwave Check Failed / Peripheral Failure / DSPFirmwareLoadError www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 113 Calibrate Output1 Lower / Output1 Upper / Output2 Lower / Output2 Upper Tables Volume/Mass Table / Linearisation Table / Delete Tables Empty Spectrum Recording Reset Customer Reset / Factory Reset / Device Restart 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 114 DESCRIPTION OF HART INTERFACE SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 115: Appendix

    Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 116 Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 117 Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) RM60 RM60 Order code (complete this code on the pages that follow) Order code (complete this code on the pages that follow) 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 118 3 This option is available if the flange has a flange face Type B1 or Raised Face (RF) 4 This option can be attached to a stainless steel flange with a low pressure rating. For more data, refer to the list of accessories. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 119: List Of Spare Parts

    Quantity Part reference number Complete electronic module XM60400000000400V0 Screws for the combined back end and HF modules F3177360000 HMI cover and cable (aluminium housing) XM60400000000501V0 HMI cover and cable (stainless steel housing) XM63400000000F01V0 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 120 1 The customer must send the original electronic module to the repair centre. Refer to the replacement procedure in this section. 2 This reference includes the gasket and screws 3 4-wire + local HART www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 121: List Of Accessories

    Stainless steel weather protection XM60400000000000V1 Blind cover (with a gasket and screws) XM60400000000000VB Gasket for the blind cover F3177420000 Hinge screws for the blind cover F3177340000 Lock screw for the blind cover F3177360000 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 122 2 This accessory is for devices with the G 1½ threaded connection. The scope of supply includes the 316L stainless steel disc, a screw and a gasket. Max. pressure: 1 barg / 14.5 psig at 20°C / 68°F. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 123: Glossary

    Horn (cone) antenna Horn (cone) antenna A common antenna for most applications. It is used for the controlled emission and collection of radar signals. Interference signals Interference signals Interference signals Interference signals False radar reflections. 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 124 Unfilled volume. See the diagrams at the end of this section. Volume Volume Volume Volume Total volume of silo contents. Waveguide Waveguide Waveguide Waveguide A PTFE component that is used to guide the emitted radar waves correctly into the horn antenna. www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 125 Figure 10-3: Measurement definitions: distance 1 Distance 2 Dead zone 3 Flange facing 4 Gas (Air) 5 Tank height 6 Ullage volume or mass Figure 10-4: Measurement definitions: level 1 Level 2 Volume or mass 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 126 APPENDIX SMARTLINE® RM60 (FMCW) www.honeywell.com/ps 34-VF-25-31 iss.4 GLO December 15 US...
  • Page 127 APPENDIX SMARTLINE® RM60 (FMCW) 34-VF-25-31 iss.4 GLO December 15 US www.honeywell.com/ps...
  • Page 128 Houston, TX 77042 Houston, TX 77042 www.honeywellprocess.com www.honeywellprocess.com www.honeywellprocess.com www.honeywellprocess.com © Honeywell International Inc. © Honeywell International Inc. © Honeywell International Inc. © Honeywell International Inc. Subject to change without notice. Subject to change without notice. Subject to change without notice.

Table of Contents