Data Corrected; Device Busy; Retries 2'20; Devicein T&Dmode - Honeywell 6000 Series Reference Manual

Disk storage subsystem
Hide thumbs Also See for 6000 Series:
Table of Contents

Advertisement

Table 2-5 (cont).
Major Status and Substatus Codes
STATUS
CODE
MPC DEVICE DATA ALERT
1011
Transmission Parity Error
000001
Inconsistent Command
000010
Checksum Error
000011
Byte Lockout
000100
EDAC Parity Error
001110
Sector" Size Error
010001
Nonstandard Sector Size
010010
Search Alert "First"
010011
Cyclic Code Error "Not First"
010100
Search Alert "Not First"
010101
Sync Byte Error
010110
Alternate Track Error
010111
EDAC Corr. -- Last Sector
011001
EDAC Corr. -- Not Last Sector
011010
EDAC Corr. — Block Count Limit
011011
EDAC Uncorrectable
011100
EDAC Corr. Short Block
011101
MPC COMMAND REJEC'J.'
1101
Illegal Procedure
000001
Illegal Logical Channel Number
000010
Illegal Suspend
000011
Continue Bit Not Set
000100
Retries
When Automatic Retry is performed by the controller, the binary number coded in the
substatus is the number cf times the retry was performed:
Once
a
(OOXOOI)
Twice
(OOXO 10)
Three Times (OOXO 1 1)
Device in T 8: D Mode
This substatus indicates that the device addressed was in the T&D mode.
Data Corrected
This substatus indicates that the control corrected data on the previous read instruction.
DEVICE BUSY
In response to an instruction, "he Device Busy status indicates that the addressed
storage unit temporarily is not available.
2-20
DB3?

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dss190Dss190b

Table of Contents