CONDITIONAL WRITE LOCK BYTE, WRITE LOCK BYTE
These instructions provide a software lock capability in the DSC when the DSC is shared
between two EUS.
READ LOCK BYTE
This instruction reads the content of any one of the 256 lock bytes contained in the DSC
memory.
SUSPEND CONTROL
This instruction is used to seize the DSC by one EUS when the DSC is connected to more
than one EUS via two or more physical channels.
RELEASE CONTROL
This instruction resets the condition set by the Suspend Control instruction.
SEND SPECIAL INTE RRUPT
This instruction obtains data from the issuing EUS and uses this data for a Special
interrupt to be sent to all connected EUS, including the issuing EUS.
READ LOGICAL CHANNEL NUMBER
This instruction sends the logical channel number, LA number, and the peripheral
subsystem interface nuInber to the EUS.
Major Status and Substatus
Table 2-5 lists the possible status returns to the various instruction terminations.
The
major statuses and substatuses are described in detail.
CHA NNE L REA DY
The Channel Ready status indicates that the last instruction received has been completed
' and no detectable errors occurred.
No Substatus
This status indicates that the controller or device is online and ready, and no detectable
error conditions exist.
When received at termination of a seek-type instruction, this sub-
status indicates that the online portion has been successfully completed.
The controller is
free to receive another instruction for that channel.