List Of Parameters - GE VAT20 Series Instruction Manual

Ac speed control equipment
Hide thumbs Also See for VAT20 Series:
Table of Contents

Advertisement

2. List of Parameters

Function
Accelerate /
Decelerate Time
Operation mode
Motor direction
V/F Pattern
Frequency
upper/lower limit
SPI frequency
JOG frequency
Operation control
Frequency Control
Carrier frequency
Torque compensation
Stop method
DC braking setting
Electronic thermal
Multifunction input
connection point
Multi-function output
Reverse lock-out
Momentary P. loss
Auto restart
Factory setting
SP2 Frequency
SP2 Frequency
Software version
Fault log
NOTE: *1: Indicate this parameter can be adjusted during running mode
*2: Please refer to Fn_25
*3: If the setting range is above 100 , the setting unit becomes 1.
*4: Only for drives with CPU version from 1.9 ( Check function F_29)
FN_
Function Description
01
Accelerate time
02
Decelerate time
03
0: Forward / Stop, Reverse / Stop
1:Run/Stop, Forward / Reverse
04
0: Forward
1: Reverse
05
V/F pattern setting
06
Frequency upper limit
07
Frequency lower limit
08
SP1 frequency
09
JOG frequency
10
0:keypad
1: external terminal
11
0:keypad
1:external terminal(0~10v/0~20mA )
2: external terminal ( 4~20mA )
12
Carrier Frequency setting
13
Torque compensation gain
14
0:decelerate stop, 1:free run stop
15
DC braking time
16
DC braking injection frequency
17
DC braking level
18
Protection on motor rated current
19
Multifunction input terminal 1 (SP1)
function
20
Multifunction input terminal 2 (RST)
function
21
Multifunction output terminal
22
0: REV run enabled
1: REV run disabled
23
0: enabled
1: disabled
24
Number of Auto-restart times
25
010: Constants initialization to 50Hz system
020: Constants initialization to 60Hz system
26
Frequency SP2
26
Frequency SP3
29
CPU program version
30
Fault Last 3 faults
Unit
0.1Sec
0.1Sec
1
1
1
0.1Hz
0.1Hz
0.1Hz
0.1Hz
1
1
1
0.1%
1
0.1S
0.1Hz
0.1%
1%
1: Jog
3: Emergency stop
4: External Base Block
5. Reset 6: Sp2
1: Operating
2: Frequency reached
1
1
1
0.1Hz
0.1Hz
21
Range
Default Note
0.1 ~ 999 S
5.0
0.1 ~ 999 S
5.0
0 ~ 1
0
0 ~ 1
0
1 ~ 6
1/4
1.0 ~ 120Hz
50/60Hz
1.0 ~ 200Hz
0.0 ~ 120Hz
0.0Hz
0 ~ 200Hz
1.0 ~ 120Hz
10Hz
1.0 ~ 200Hz
1.0~ 10.0Hz
6Hz
1.0 ~ 200Hz
0 ~ 1
0
0 ~ 2
0
1 ~ 5
5
1 ~ 10
0.0 ~ 10.0%
0.0%
0 ~ 1
0
0.0 ~ 25.5S
0.5S
1 ~ 10Hz
1.5Hz
0.0 ~ 20.0%
8.0%
50 ~ 100%
100%
(0-200
2: Sp1
2
5
3: Fault
3
0 ~ 1
0
0 ~ 1
0
0 ~ 5
0
1.0 ~ 200Hz
20
1.0 ~ 200Hz
30
*1*3
*1*3
*1
*2
*2*3
*4
*3
*4
*3
*4
*4
*4
*1
*4
*4
*2
*4
*4