Connection Diagram; Clock/Data And Rs-485 Interface; Synchronization - Honeywell Accentic proX2 Mounting And Operating Instructions

Reader with keypad, rs-485 and clock/data interface, wiegand interface
Table of Contents

Advertisement

Available languages

Available languages

22
5.

Connection diagram

A plug has been soldered to the cable of the reader at the factory especially for test and
premounting sets. For the final installation, it usually has to be cut off.
5.1

Clock/Data and RS-485 interface

The reader has the interfaces
up, the reader automatically identifies the interface that is in use.
Clock/Data:
To ensure reliable functioning, ensure that a possible extension of the 6 m connecting
cable does not exceed 200 m. A JY(ST)Y 6x2x0.6 mm cable can be used for extension
purposes.
RS-485:
The reader can be used remotely at a distance of max. 1200 m. We recommend
using a Cat 5 connecting cable.
If the reader is the last user on the RS-485 module bus, a distributor with a 120 Ohm
terminating resistor (from D to D*) must be installed in front of the reader.
For further information, refer to the description of the corresponding central control
unit.
Attention:
Do not confuse the data
lines A and B, otherwise the
device will not function!
F
i
1
2
3
5
4
6
7
8
9
3
r
0
Concerns
ACS-1, ACT, ACS-2, ACS-2 plus and ACS-8:
If the
Clock/Data
interface is used, connect a
(brown).
5.2

Synchronization

In order to prevent densely packed readers from affecting one another, they must be connected to
one another via the "Synchronization" line (black). Up to 4 readers can be synchronized in this
manner.
Synchronization is required at a distance of
The transponder that is identified first has priority during the read process. The other readers
involved are inactive. After a period of 5 sec. they are reactivated.
Reader 1
sw
Leitung für Synchronisation
Mounting and Operating Instructions - proX2-reader "Accentic" with keypad
clock/data
and
grey/pink
£1 m
Reader 1
sw
RS-485
that can be used alternatively. When started
red
blue
yellow
white
black
violet
grey
red/blue
green
brown
pink
(free)
Shield
680 W
resistor from "+U_b" (red) to "LED yellow"
(approximate value).
+U_b (9 V bis 30 V DC)
0 V
A (D)
RS-485
B (D*)
Synchronization
(see below)
Enable RS-485
CLK (D1)
DATA (D0)
LED green
LED yellow
LED red
Reader 1
sw
W
680
max. 4