Installation; Parts Description - Makita AT638A Instruction Manual

Narrow crown stapler
Hide thumbs Also See for AT638A:
Table of Contents

Advertisement

Available languages

Available languages

WARNING:
MISUSE or failure to follow the
safety rules stated in this instruction manual may
cause serious personal injury.
Symbols
The followings show the symbols used for tool.
Read and understand tool labels and man-
ual. Failure to follow warnings could result
in death or serious injury.
Operators and others in work area must
wear safety glasses with side shields.
Keep fingers away from trigger when
not driving fasteners to avoid accidental
discharge.

PARTS DESCRIPTION

2
► 1. Trigger 2. Nose adapter (contact element)
3. Hook 4. Magazine
4
3
1

INSTALLATION

Selecting compressor
2.5
2
1.5
2
1
0.5
0
10
1. Stapling frequency (times/min) 2. Compressor air
output per minute (CFM (ft
PSIG) 4. 0.66 MPa (95 PSIG) 5. 0.49 MPa (70 PSIG)
The air compressor must comply with the requirements
of ANSI B19.3.
Select a compressor that has ample pressure and air
output to assure cost-efficient operation. The graph
shows the relation between stapling frequency, applica-
ble pressure and compressor air output.
Thus, for example, if stapling takes place at a rate of
approximately 50 times per minute at a compression of
0.83 MPa (120 PSIG), a compressor with an air output
3
over 1.5 CFM ( ft
/minute) is required.
Pressure regulators must be used to limit air pressure to
the rated pressure of the tool where air supply pressure
exceeds the tool's rated pressure. Failure to do so may
result in serious injury to tool operator or persons in the
vicinity.
Selecting air hose
CAUTION:
Low air output of the compressor,
or a long or smaller diameter air hose in relation
to the stapling frequency may cause a decrease in
the driving capability of the tool.
4 ENGLISH
20
30
40
50
1
3
/min.)) 3. 0.83 MPa (120
3
4
5

Hide quick links:

Advertisement

Table of Contents
loading