DS1000/2000 Correspondence Course
System Configuration
8-Slot Cabinet Default Configuration
24
DS1000/2000 Workbook
it does, you won't have to make any of the changes in the slot assignments
(Changing System Configuration/Slot Assignment on page 84).
Always observe the System Load Factor when configuring your system.
Note:
Following is the default PCB configuration for your 8-slot cabinet. Note that you
must always install a 16DSTU PCB in slot 1. This assignment is not programma-
ble. The default configuration supports 24 trunks and 80 extensions (24 x 80).
Your system will automatically load the system software for your 8-slot cabinet
during system startup. You do not need to install the RFI Suppressor Assemblies
on your extension and trunk cabling.
In an 8-slot cabinet, you can only install A series PCBs:
CPU PCB P/N 80025A
Power Supply P/N 80005A
16DSTU Digital Station PCB P/N 80021A
8 ASTU 8 Port Analog Station PCB P/N 80041A
4ASTU 4 Port Analog Station PCB P/N 80040A
8ATRU 8 Port Analog Trunk PCB P/N 80011A
4ATRU 4 Port Analog Trunk PCB P/N 80010A
Slot
1
2 - 8
Review the default configuration above to see if it meets your site requirements. If
it does, you won't have to make any of the changes in the slot assignments
(Changing System Configuration/Slot Assignment on page 84).
PCB
Extensions
16DSTU
300-315
Undefined
NEC America