Backflow preventer
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

BA295D-3/4WH
BA295D-3/4WHS
Einbauanleitung Installation instructions
Systemtrenner
Anleitung zum späteren Gebrauch aufbewahren!
Keep instructions for later use!
Backflow Preventer

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell BA295D-3WH

  • Page 1 BA295D-3/4WH BA295D-3/4WHS Einbauanleitung Installation instructions Systemtrenner Anleitung zum späteren Gebrauch aufbewahren! Keep instructions for later use! Backflow Preventer...
  • Page 2: Montage

    Ablauf nach unten 3. Systemtrenner mit dem Zapfventil mit mitgelieferter Zapf- hahnplombierschelle verplomben 4. Bei Bedarf 1" IG auf 3/4" AG Gewindeadapter montieren 5. Bei Einsatz im Gebäude Ablaufanschluss montieren 6. Absperrventil vor der Armatur öffnen Honeywell GmbH MU1H-1248GE23 R1114...
  • Page 3: Wartung

    10. Absperrventil vor der Armatur öffnen • Gehäuse aus entzinkungsbeständigem Messing • Kartuscheneinsatz aus hochwertigem Kunststoff • Rückflussverhinderer aus hochwertigem Kunststoff • Dichtelemente aus trinkwassergeeigneten Elastomeren Die örtlichen Vorschriften zur ordnungsgemäßen Abfall- verwertung bzw. Beseitigung beachten! MU1H-1248GE23 R1114 Honeywell GmbH...
  • Page 4: Störungen / Fehlersuche

    - verchromt AE295D-C Prüfgerät TK295 bzw. TKA295 Schmutzfänger S295D Kartuscheneinsatz 0903733 Rückflussverhinderereinsatz 2110200 Verschlussstopfenset (je 5 Stück) aus Kunststoff für BA295D-3/4WH S06K-1/4 aus Messing für BA295D-3/4WHS PS295STN Plombierschelle (10 Stück) PS295D Halteklammer (10 Stück) HK295D Zapfhahnplombierschelle PS295D-Z Honeywell GmbH MU1H-1248GE23 R1114...
  • Page 5 3. Seal backflow preventer and tap using included seal bracket 4. Install threaded adapter 1" IG to 3/4" AG if necessary 5. For inside installation fit discharge pipe connection 6. Open shutoff valve upstream the valve Honeywell GmbH MU1H-1248GE23 R1114...
  • Page 6: Operational Maintenance

    • High-grade synthetic material check valve 9. Insert discharge connection • Sealing elements made of elastomer materials suitable for 10. Open shutoff valve upstream the valve drinking water Observe the local requirements regarding correct waste recycling/disposal! MU1H-1248GE23 R1114 Honeywell GmbH...
  • Page 7: Troubleshooting

    Cartridge insert 0903733 Check valve insert 2110200 Set of blanking plugs (5 pieces each) plastic for BA295D-3/4WH S06K-1/4 brass for BA295D-3/4WHS PS295STN Seal brackets (10 pieces) PS295D Retaining clip (10 pieces) HK295D Seal bracket for tap PS295D-Z Honeywell GmbH MU1H-1248GE23 R1114...
  • Page 8 Automation and Control Solutions Honeywell GmbH Manufactured for and on behalf of the Environmental and Combustion Controls Division of Hardhofweg Honeywell Technologies Sàrl, Z.A. La Pièce 16, 74821 MOSBACH 1180 Rolle, Switzerland by its Authorised Represen- tative Honeywell GmbH GERMANY...
  • Page 9 8.1.1 8.1.2 8.2.1 8.3.1 8.3.2 8.3.3 MU1H-1248GE23 R1114 Honeywell GmbH...
  • Page 10 4. Technical data ........5 5. Scope of delivery ....... 5 6. Options ..........5 7. Assembly ..........5 8. Maintenance ........6 9. Disposal ..........6 10. Troubleshooting ......... 7 11. Spare Parts ........7 12. Accessories ........7 MU1H-1248GE23 R1114 Honeywell GmbH...

This manual is also suitable for:

Ba295d-4whBa295d-4whsBa295d-3whs

Table of Contents