Honeywell Ex-Or CDH4U5 Installation And Commissioning Instructions

Honeywell Ex-Or CDH4U5 Installation And Commissioning Instructions

4-channel programmable intelligent lighting control module

Advertisement

CDH4U5
4-Channel Programmable
Intelligent Lighting Control Module
Installation and Commissioning Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Ex-Or CDH4U5

  • Page 1 CDH4U5 4-Channel Programmable Intelligent Lighting Control Module Installation and Commissioning Instructions...
  • Page 2: Electrical Connections

    Introduction Electrical Connections The CDH4U5 is an intelligent LCM providing connections for multiple The connections to this equipment should be made only by a suitably luminaires*, up to 5 presence detectors and up to 5 SELV inputs. The product qualified person and in accordance with the current wiring regulations. simplifies installation whilst providing an intelligent lighting control system.
  • Page 3 b) Essential and Non-Essential Supplies ESSENTIAL NON-ESSENTIAL SUPPLY SUPPLY Earth not shown for clarity Ballast Ballast Ballast Ballast Ballast used MAINS INPUT N1 L1 VOLT FREE CHANNELS VOLT FREE CHANNELS N2 L2 + 1 - + 2 - + 3 - + 4 - 1 - 1 2 - 2...
  • Page 4 c) Two Supplies Equally Likely to Drop Out SUPPLY 1 SUPPLY 2 Earth not shown for clarity Ballast Ballast Ballast Ballast Ballast Can be Maintained derived Live from Emergency either Luminaire supply MAINS INPUT N1 L1 VOLT FREE CHANNELS VOLT FREE CHANNELS N2 L2 N2 L2 + 1 -...
  • Page 5 Connecting Presence Detectors The following SELV detectors are designed to interface to the CDH4U5: MLS2500CDR Corner-mount Microwave presence detector with photocell, semi-flush mounted. Available with surface mount (SM suffix). MLS2401CDR 360° Microwave presence detector with photocell, flush mounted. Available in surface mount version (SM suffix). MLS2001CDR 360°...
  • Page 6 Commissioning The LCM is commissioned using a dedicated programme running on a Windows-based computer. Commissioning settings may then be directly uploaded from the computer to the LCM or transferred to an HP2000 hand-held programmer for easy upload on site. Communication from the PC can be by means of a USB infrared transceiver which can signal directly to the LCM’s on-board infrared port over a short range or via any attached presence detector from beneath (range: 1-3m).
  • Page 7 Product Applications The CDH4U5 may be used in various different applications, e.g. warehouse, school, hospital etc having a single supply or two different supplies. For more details on the differing applications, please refer to Application Note AN4027. Connections Dimming Channels Detectors Mains Switches...
  • Page 8 * Planned - please contact Sales Department for latest information Ex-Or Novar ED&S Limited Haydock Lane, Haydock, Merseyside WA11 9UJ Tel: +44 (0)1942 719229 Fax: +44 (0)1942 508753 Email: technicalsales.ex-or@honeywell.com www.ex-or.com At the end of their useful life the packaging and product should be disposed of via a suitable recycling centre.