Functional Description; Installing Or Removing Battery Cartridge - Makita DLS713 Instruction Manual

Cordless slide compound miter saw
Hide thumbs Also See for DLS713:
Table of Contents

Advertisement

Available languages

Available languages

Then tighten the screws firmly to secure the holders and
the holder assemblies.
FUNCTIONAL
DESCRIPTION
WARNING:
Always be sure that the tool is switched off
and the battery cartridge is removed before
adjusting or checking the functions on the
tool. Failure to switch off and remove the bat-
tery cartridge may result in serious personal
injury from accidental start-up.
Installing or removing battery
cartridge
CAUTION:
Always switch off the tool before
installing or removing of the battery cartridge.
CAUTION:
Hold the tool and the battery car-
tridge firmly when installing or removing battery
cartridge. Failure to hold the tool and the battery
cartridge firmly may cause them to slip off your hands
and result in damage to the tool and battery cartridge
and a personal injury.
3
► 1 . Red indicator 2. Button 3. Battery cartridge
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Insert it all the way until it locks in place
with a little click. If you can see the red indicator on the
upper side of the button, it is not locked completely.
CAUTION:
Always install the battery cartridge
fully until the red indicator cannot be seen. If not,
it may accidentally fall out of the tool, causing injury to
you or someone around you.
CAUTION:
Do not install the battery cartridge
forcibly. If the cartridge does not slide in easily, it is
not being inserted correctly.
Battery protection system (Lithium-
ion battery with star marking)
► 1 . Star marking
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically
cuts off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
2
1
Indicating the remaining battery
capacity
Only for battery cartridges with the indicator
► 1 . Indicator lamps 2. Check button
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
8 ENGLISH
1
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the trigger switch on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
trigger switch again to restart.
If the tool does not start, the battery is over-
heated. In this situation, let the battery cool
before pulling the trigger switch again.
Low battery voltage:
The remaining battery capacity is too low
and the tool will not operate. In this situation,
remove and recharge the battery.