Honeywell GAS DETECTOR
The autonomous gas sensor (hereinafter referred to as the sensor) is a home
device for detecting a leak of natural gas (the main component is methane),
which, in the case of determining a high concentration of combustible gas
(methane) in the room, produces a light-sound alarm or sends a warning message
to the connected device.
Accessories
Alarm x1
Mounting plate x1
Battery x1
Holes for sound
«Sound/Self control» button
Overview
The instruction x1
Plug dowel x2
Screw x2
Double-sided adhesive tape x2
Holes for detecting a gas
Setup instructions
1. Connection terminal, output signal and device connection
* Even if the connection terminal is not connected to the device, the sensor will still
function.
* If you need to connect an electromagnetic solenoid valve or an output fan to the
wiring, please ask your dealer for assistance.
Сonnection terminal

Advertisement

loading

Summary of Contents for Honeywell JTQJ-BF-01LM/BW

  • Page 1 Setup instructions 1. Connection terminal, output signal and device connection Honeywell GAS DETECTOR * Even if the connection terminal is not connected to the device, the sensor will still function. Overview * If you need to connect an electromagnetic solenoid valve or an output fan to the wiring, please ask your dealer for assistance.
  • Page 2: Installation

    Installation the mounting plate to the ceiling; d) Attach the main alarm panel to the mounting panel in accordance with all the reference marks, go clockwise until you hear a characteristic click that indicates the fixation of the device. 1. Fastening with screws a) Insert the battery into the battery compartment, press and hold the «Sound / Self-check»...
  • Page 3: Selecting An Installation Location

    Selecting an installation location Functions Indicator status Wall mounting: the distance between the gas sensor and the gas equipment or valve should not be more than 4 meters, the distance from the sensor installation to the ceiling should be less than 0.3 meters, but do not install the sensor directly above the gas equipment.
  • Page 4: Main Parameters

    Main parameters operation. 3. Alarm If the device has no faults, but as a result of exceeding the permissible level of gas concentration in the room, the audible alarm turns on, the red indicator lights up, and the signal sounds. To turn off the signal, press the «Sound / Self-Diagnosis» button, and after about 70 seconds the device will resume its operation.
  • Page 5: Faults And Troubleshooting

    Cautions Faults and troubleshooting 1. This sensor is used only for pipeline gas (methane), can not be used to determine liquefied gas in cylinders; 2. It is forbidden to make changes of the internal structure of the device; 3. Do not directly expose the highly concentrated flammable gas to the sensor (eg lighter gas, clean natural gas, etc.), this may result in a partial / total reduction in the sensitivity of the sensor or its damage;...
  • Page 6: Warranty

    Actions on gas leakage Warranty Warranty service is carried out in accordance with the law on «Consumer Rights» 1. When the alarm is on, do not turn on any electrical appliances; and «Product Quality Law». Warranty service includes: 2. It is forbidden to disconnect the sensor from the power source, it can automatically close the solenoid valve and turn on the fan (if it is);...