Installing the AlarmNet GSML/GSMVL Communications Device
1. Install the module into the control back plate and secure it with the three provided screws.
2. Insert the antenna into the retaining slots in the control back plate.
3. Use double-stick tape to secure antenna to the control back plate.
4. Connect the provided communications cable between the GSML/GSMVL module and the control's PC
board. This cable provides DC power and ground for the module and data in/data out connections.
5. If using the GSMVL, connect the provided shielded audio cable between the GSMVL module and the
control's PC board.
SCREW (3)
AUDIO CABLE
(GSMVL ONLY)
Installing the GSML/GSMVL Communications Module
GSML/GSMVL Programming
If you are installing a GSML/GSMVL Communications Device, it must be programmed in the control via the
following new and revised Data Fields.
*55 Reporting Channels
*77 Dynamic Signaling Delay/Dynamic Signaling Priority
*78 Programmable Tone Generation Time
GSMVL
COMMUNICATIONS