Parameter Descriptions
O-54 Reversing Select
Option:
[0]
Digital
input
3
3
[1]
Bus
[2]
Logic AND
[3]
Logic OR
*
O-55 Set-up Select
Option:
[0]
Digital
input
[1]
Bus
[2]
Logic AND Activates the set-up selection via the network/
[3]
Logic OR
*
O-56 Preset Reference Select
Option:
[0]
Digital
input
[1]
Bus
[2]
Logic AND Activates Preset Reference selection via the
[3]
Logic OR
*
92
AF-650 GP Programming Guide
Function:
Select control of the frequency converter
reverse function via the terminals (digital
input) and/or via the fieldbus.
Activates the Reverse command via the serial
communication port or fieldbus optionmodule.
Activates the Reverse command via the
fieldbus/serial communication port, AND
additionally via one of the digital inputs.
Activates the Reverse command via the
fieldbus/serial communication port OR via one
of the digital inputs.
Function:
Select control of the frequency converter set-
up selection via the terminals (digital input)
and/or via the network.
Activates the set-up selection via a digital
input.
Activates the set-up selection via the serial
communication port or network option
module.
serial communication port, AND additionally via
one of the digital inputs.
Activate the set-up selection via the network/
serial communication port OR via one of the
digital inputs.
Function:
Select control of the frequency converter
Preset Reference selection via the terminals
(digital input) and/or via the network.
Activates Preset Reference selection via a
digital input.
Activates Preset Reference selection via the
serial communication port or network option
module.
network/serial communication port, AND
additionally via one of the digital inputs.
Activates the Preset Reference selection via the
network/serial communication port OR via one
of the digital inputs.
3.10.6 O-8# Drive Port Diagnostics
O-80 Bus Message Count
Range:
Function:
0
[0 - 0] This parameter shows the number of valid
*
messages detected on the network.
O-81 Bus Error Count
Range:
Function:
0
[0 - 0] This parameter shows the number of messages with
*
faults (e.g. CRC fault), detected on the network.
O-82 Slave Messages Rcvd
Range:
Function:
0
[0 - 0] This parameter shows the number of valid
*
messages addressed to the slave, sent by the
frequency converter.
O-83 Slave Error Count
Range:
Function:
0
[0 - 0] This parameter shows the number of error
*
messages, which could not be executed by the
frequency converter.
3.10.7 O-9# Bus Jog Feedback
Parameters to configure the Jog Speed when drive is in
Bus Control.
O-90 Bus Jog 1 Speed
Range:
100 RPM
[0 - par. F-17
*
RPM]
O-91 Bus Jog 2 Speed
Range:
200 RPM
[0 - par. F-17
*
RPM]
DET-618C
Function:
Enter the jog speed. Activate this
fixed jog speed via the serial port
or network option.
Function:
Enter the jog speed. Activate this
fixed jog speed via the serial port
or network option.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents